The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF32X175S-06E is a genuine double-acting ISO 15552 cylinder with a Ø32mm bore, 175mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF32X175S-06E is a double-acting ISO 15552 profile cylinder featuring an integrated 4M210-06 5/2 solenoid valve. Driven by an AC24V terminal coil consuming 3.5 VA, the valve offers a 14.0 mm2 effective area (Cv 0.78) and switches at up to 5 cycles per second. Because the manifold routes air through an O8 x O5 PU tube directly to the cylinder, you eliminate remote plumbing and save panel space.
The assembled unit operates safely within 0.15-0.8 MPa, as the valve pressure rating dictates the practical working range rather than the cylinder's 1.0 MPa limit. Delivering 402 N of push force at 0.5 MPa, it includes a magnet for position sensing with CMSE reed or DMSE electronic switches. The factory default setting retracts the rod when the coil is energised, but you can reposition the valve to extend on signal.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF32X175S-06E |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 175 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/8 |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC24V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 32×175 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| E | Coil voltage AC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines where running separate valve lines is costly, the integrated AC24V valve lets this cylinder switch itself directly from a single coil signal.
Saves valuable panel space by mounting the 4M210 valve directly on the profile body, providing 402 N of push force without the plumbing bulk of remote valve banks.
Equipped with a standard magnet (-S) to seamlessly interface with CMSE reed and DMSE electronic sensors for precise stroke verification in automated lines.
Choose this 32mm bore if your application requires around 402 N push force at 0.5 MPa; step up to the 40mm bore for 628 N if handling heavier loads, or down if less force is needed. The self-valved SAIF architecture is ideal for decentralized machine stations where running separate valve tubing is costly or space-prohibitive. With a 175mm stroke, ensure adequate guide support to prevent excessive side-loading on the rod.
For replacements, match the 32mm bore, 175mm stroke, 1/8" cylinder port, 06 (1/8") valve port, AC24V voltage, terminal entry, PT thread, and the -S magnet. Remember that the built-in 5/2 valve routes air but does not lock the load mechanically; if you need true position holding under pressure loss, consider the SAIL lock series instead.
Quick checklist
The 32mm bore generates 402 N of push force at 0.5 MPa. The built-in 4M210-06 valve has an effective area of 14.0 mm2 (Cv 0.78) and can cycle up to 5 times per second.
Yes, the integrated 5/2 valve allows the cylinder to control itself from one AC24V coil signal, eliminating the need for remote plumbing. By default, the rod retracts when energised but can be reconfigured to extend. Note that the valve routes air and does not mechanically lock the load.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.