The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF32X175S-06F is a genuine double-acting ISO 15552 cylinder with a Ø32mm bore, 175mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF32X175S-06F is a double-acting ISO 15552 profile cylinder featuring an integrated 4M210-06 5/2 solenoid valve. Driven by a DC12V terminal coil drawing 3.0W, it delivers a 402N push force at 0.5MPa. The valve offers a 14.0mm2 effective area (Cv 0.78) and switches up to 5 cycles per second. Because the cylinder body rates to 1.0MPa but the internal pilot valve operates at 0.15-0.8MPa, the practical working range for this assembly is 0.15-0.8MPa.
This self-contained unit eliminates remote plumbing, using an O8xO5 PU tube between the manifold block and cylinder. The cylinder port is PT1/8, while the valve port is 1/8. Factory set to retract the rod when energised, the valve can be repositioned to extend on signal. The -S magnet supports CMSE reed and DMSE electronic sensors for position feedback.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF32X175S-06F |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 175 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/8 |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | DC12V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 32×175 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| F | Coil voltage DC12V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines with multiple isolated stations, using the built-in 4M210-06 valve to eliminate long air lines from a central panel.
Fits into tight mechanical spaces where a separate 5/2 valve and manifold block would exceed the available envelope.
The DC12V terminal coil is well-suited for battery-backed or low-voltage industrial control systems requiring 3.0W power.
Choose the 32mm bore when 402N push force at 0.5MPa is sufficient; stepping up to the 40mm bore yields 628N. The SAIF32X175S-06F excels in decentralized stations where running separate valve tubing is costly, saving panel space and wiring. Its DC12V terminal coil suits low-voltage control systems. For load-holding applications, note that the 5/2 valve routes air but does not lock the piston; consider AirTAC SAIL for pneumatic locking. Replacement requires matching the 32mm bore, 175mm stroke, 06 valve port, DC12V voltage, PT thread, and -S magnet. At 175mm stroke, ensure adequate guide support to manage side loads.
Quick checklist
At 0.5MPa, it provides 402N of push force and 345N of pull force. The built-in 4M210-06 valve has a 14.0mm2 effective area (Cv 0.78) and operates up to 5 cycles per second.
No, the 5/2 valve routes air but does not lock the load. By default, it retracts the rod when the DC12V coil is energised, but it can be repositioned to extend on signal. For true load holding, use an AirTAC SAIL lock cylinder.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.