The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF32X200-08A is a genuine double-acting ISO 15552 cylinder with a Ø32mm bore, 200mm stroke and a built-in 4M210-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF32X200-08A is a double-acting ISO 15552 profile cylinder featuring an integrated 4M210-08 5/2 solenoid valve. Driven by an AC220V terminal coil drawing 3.5 VA, it delivers a 402N push force at 0.5 MPa. Because the cylinder body rates to 1.0 MPa but the internal piloted valve operates at 0.15-0.8 MPa, the practical working range for this assembled unit is 0.15-0.8 MPa. The valve provides a 16.0 mm2 flow area (Cv 0.89) and switches at up to 5 cycles per second.
By default, the piston rod retracts when the coil is energised, though this can be reconfigured to extend-when-energised simply by repositioning the valve. The manifold links the valve to the cylinder using O8 x O5 PU tubing, meaning the 1/4" valve port differs from the cylinder's 1/8" port. This self-contained design eliminates remote plumbing, saving panel space for decentralized machine stations.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF32X200-08A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 200 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/8 |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-08 (5/2) |
|---|---|
| Valve flow | 16.0 mm² (Cv 0.89) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 32×200 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M210-08. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines with multiple actuation points, eliminating long tubing runs by switching locally via the integrated valve.
Fits into tight machinery envelopes where mounting a separate directional control valve is structurally impossible.
Upgrades existing pneumatic setups by replacing a standard cylinder and remote plumbing with a self-switching unit.
Choose this 32mm bore when you need compact actuation delivering 402N push and 345N pull at 0.5 MPa; stepping up to the 40mm bore raises push force to 628N if your payload demands more margin. The self-valved SAIF architecture is ideal when running separate valve tubing is costly or space-prohibitive, as one AC220V terminal connection directly drives the actuator. For stroke lengths of 200mm or more, ensure adequate side-load guidance to prevent rod binding.
When ordering a replacement, verify the 32mm bore, 200mm stroke, 1/4" valve port, AC220V voltage, terminal entry, and PT tapered threads. Note that this SKU lacks the -S magnet, so it cannot host CMSE reed or DMSE electronic sensors without modification. Remember that the 5/2 valve routes air but does not mechanically lock the load; if static holding is required, consider a SAIL lock cylinder.
Quick checklist
At 0.5 MPa, this 32mm bore cylinder generates 402N of push force and 345N of pull force. The built-in 4M210-08 valve has an effective flow area of 16.0 mm2 (Cv 0.89).
No, it uses a built-in 4M210 5/2 valve driven directly by an AC220V terminal coil. By factory default, energising the coil retracts the rod, but the valve can be repositioned to extend-when-energised.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.