The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF32X200S-06C is a genuine double-acting ISO 15552 cylinder with a Ø32mm bore, 200mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF32X200S-06C is a double-acting ISO 15552 profile cylinder with a built-in 4M210-06 5/2 solenoid valve. This integrated valve delivers a 14.0 mm2 effective area (Cv 0.78) and mounts directly via a manifold block using O8 x O5 PU tubing. Driven by an AC110V terminal coil drawing 3.5 VA, it features IP65 protection and a rapid 0.05 s activation time. The -S magnet option enables position tracking with CMSE reed and DMSE electronic sensors.
Although the cylinder body rates to 1.0 MPa, the practical operating range for this valved assembly is 0.15-0.8 MPa. At 0.5 MPa, the 32 mm bore generates 402 N of push force and 345 N of pull force. Factory set to retract the rod when the coil is energised, the valve can be repositioned to extend-when-energised. By switching itself from one coil signal, it eliminates remote valves, reducing tubing and panel space for decentralized machine stations.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF32X200S-06C |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 200 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/8 |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC110V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 32×200 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| C | Coil voltage AC110V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines with distributed stations, cutting panel space by mounting the 4M210 valve directly on the cylinder.
Fits space-tight machinery where running remote valve tubing is impractical, delivering 402 N push force at 0.5 MPa.
Simplifies machine upgrades by replacing a separate cylinder and remote valve with a single self-switching AC110V unit.
Choose this 32 mm bore when compact, lower-force actuation is needed; stepping up to the 40 mm bore raises push force to 628 N at 0.5 MPa. The SAIF32X200S-06C excels in decentralized installations where running separate valve tubing is costly, as the integrated 4M210 valve handles switching directly. The AC110V terminal connection suits standard plant power. For stroke lengths of 200 mm or greater, ensure adequate side-load support and use a guide rail to prevent rod binding. Remember that the 5/2 valve routes air but does not lock the load; for position holding, consider the SAIL lock cylinder. To replace this unit, match the 32 mm bore, 200 mm stroke, 1/8" cylinder port, 06 (1/8") valve port, AC110V voltage, PT thread, terminal entry, and -S magnet.
Quick checklist
The 32 mm bore generates 402 N push and 345 N pull force at 0.5 MPa. The built-in 4M210-06 5/2 valve provides a 14.0 mm2 effective area (Cv 0.78) with a maximum frequency of 5 cycles per second.
The integrated 5/2 valve switches the cylinder from a single AC110V terminal coil signal (3.5 VA, IP65). Factory set to retract when energised, the valve can be repositioned to extend-when-energised, eliminating the need for a separate remote valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.