The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF32X300-06B is a genuine double-acting ISO 15552 cylinder with a Ø32mm bore, 300mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF32X300-06B is a double-acting ISO 15552 profile cylinder featuring a built-in 4M210-06 5/2 solenoid valve. This integrated manifold design eliminates the need for a separate remote valve, significantly reducing panel space and plumbing complexity for decentralized machine stations. The unit delivers a push force of 402N at 0.5MPa and operates efficiently across a 30-800mm/s speed range.
Equipped with a DC24V terminal electrical entry consuming just 3.0W, the coil offers IP65 protection and a rapid 0.05s activation time. While the cylinder body itself is rated for 1.0MPa, the practical operating pressure for the assembled SAIF unit is 0.15-0.8MPa due to the valve's internal pilot limits. By factory default, the piston rod retracts when the coil is energised, but this can be reconfigured to extend-when-energised simply by repositioning the valve.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF32X300-06B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 300 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/8 |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 32×300 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines with multiple stations, eliminating long tubing runs from a central manifold by switching the 32mm bore directly via the built-in 4M210 valve.
Perfect for tight equipment layouts where panel space is at a premium, using the integrated valve manifold to minimize external plumbing.
Suits machinery upgrades where adding a remote valve island is too costly, allowing direct 24V DC coil control right at the cylinder.
Choose this 32mm bore model when your application requires the compact force of 402N push at 0.5MPa and a 300mm stroke. If your machine needs greater thrust, stepping up to the 40mm bore yields 628N push at 0.5MPa. The self-valved SAIF architecture is highly advantageous for space-tight machines where routing pneumatic tubing from a centralized valve island is costly or impractical. It switches directly from one 24V DC coil signal.
For replacements, verify the 32mm bore, 300mm stroke, PT1/8 cylinder port, 4M210-06 valve with 1/8 port code, DC24V voltage, terminal entry, and PT thread type. Note that -S is not specified, so it lacks a magnet for CMSE or DMSE sensors. Since the 300mm stroke is relatively long for a 32mm bore, ensure adequate side-load guidance to prevent rod binding and premature seal wear. Remember that the 5/2 valve routes air but does not mechanically lock the load; for true position holding, consider the SAIL lock cylinder.
Quick checklist
The 32mm bore cylinder provides a push force of 402N and a pull force of 345N at 0.5MPa. The built-in 4M210-06 5/2 valve has an effective area of 14.0mm2 (Cv 0.78) and a maximum frequency of 5 cycles per second.
No separate remote valve is needed. By factory default, the rod retracts when the DC24V coil is energised. You can reconfigure it to extend-when-energised by repositioning the valve on the manifold block.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.