The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF32X75S-06E is a genuine double-acting ISO 15552 cylinder with a Ø32mm bore, 75mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF32X75S-06E is a double-acting ISO 15552 profile cylinder featuring a built-in 4M210-06 5/2 solenoid valve. This specific SKU is configured with an AC24V terminal electrical entry, drawing 3.5 VA, and includes a magnet for CMSE reed and DMSE electronic sensors. Equipped with a 1/8 PT cylinder port and a 1/8 valve port, the integrated valve provides an effective flow area of 14.0 mm2 (Cv 0.78). Because the valve operates at 0.15-0.8 MPa, this defines the practical working pressure range for the assembled unit, even though the cylinder body rates to 1.0 MPa.
In its factory setting, the piston rod retracts when the coil is energised, but you can reconfigure it to extend-when-energised simply by repositioning the valve. The 32mm bore generates 402N of push force at 0.5 MPa. By controlling itself from a single coil signal, this unit eliminates remote plumbing and saves panel space, making it ideal for decentralized stations across large machines. The manifold connects to the cylinder using O8 x O5 PU tubing.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF32X75S-06E |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 75 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/8 |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC24V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 32×75 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| E | Coil voltage AC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates the need for a centralized valve manifold, allowing independent 24V AC control of clamping actions directly at the workstation.
The integrated 4M210 valve and profile barrel save valuable envelope space in tight electronic testing machinery without sacrificing sensor compatibility.
Ideal for upgrading older pneumatic setups where running new valve tubing back to a control panel is costly and impractical.
Select this 32mm bore when your application requires up to 402N of push force at 0.5 MPa; if you need greater thrust, stepping up to the 40mm bore yields 628N under the same pressure. The SAIF32X75S-06E is the optimal choice over a plain cylinder and separate remote valve when you need to minimize wiring and tubing in decentralized installations. To replace this unit accurately, match the 32mm bore, 75mm stroke, PT1/8 cylinder port, 4M210-06 valve, AC24V voltage, terminal entry, PT thread, and the -S magnet. Note that the built-in 5/2 valve routes air but does not lock the load; for position holding under zero pressure, consider the SAIL lock cylinder instead.
Quick checklist
The 32mm bore generates 402N of push force and 345N of pull force at 0.5 MPa. The built-in 4M210-06 5/2 valve provides an effective flow area of 14.0 mm2 (Cv 0.78) with a maximum frequency of 5 cycles per second.
By default, the factory setting retracts the piston rod when the AC24V coil is energised. You can reconfigure it to extend-when-energised by repositioning the valve. Because the 5/2 valve is integrated directly onto the cylinder, no separate remote valve is needed, saving significant panel space.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.