
The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF32X80S-08C is a genuine double-acting ISO 15552 cylinder with a Ø32mm bore, 80mm stroke and a built-in 4M210-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF32X80S-08C is a double-acting ISO 15552 profile cylinder equipped with a built-in 4M210-08 5/2 solenoid valve, providing a Cv of 0.89. It features a 32mm bore, an 80mm stroke, and a carbon steel piston rod. Driven by an AC110V terminal-entry coil drawing 3.5 VA, it achieves IP65 protection and a 0.05s activation time. Because the valve manifold uses O8xO5 PU tubing, the 1/4" valve port differs from the 1/8" cylinder port. Although the cylinder body rates to 1.0 MPa, the practical operating range for this assembled SAIF unit is 0.15-0.8 MPa.
Out of the box, the factory setting retracts the piston rod when the coil is energised; you can reconfigure it to extend-when-energised simply by repositioning the valve. The integrated manifold switches the cylinder directly from one coil signal, eliminating remote plumbing and saving panel space for decentralized machine stations. Equipped with a magnet (-S), this model supports AirTAC CMSE reed and DMSE electronic sensors for precise positioning.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF32X80S-08C |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 80 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/8 |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-08 (5/2) |
|---|---|
| Valve flow | 16.0 mm² (Cv 0.89) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC110V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 32×80 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M210-08. |
| C | Coil voltage AC110V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates remote valve plumbing by driving the 32mm bore directly from its built-in 4M210 valve, saving panel space across large automated lines.
Provides 402N of push force at 0.5 MPa in tight tooling spaces where running separate valve tubing is impractical.
Simplifies machine upgrades by using a single AC110V coil signal to control actuation, reducing both pneumatic and electrical wiring complexity.
Choose this 32mm bore when you need compact actuation delivering 402N push force at 0.5 MPa; step up to the 40mm bore if your application requires 628N push force. The self-valved SAIF32X80S-08C excels over a separate cylinder and remote valve in space-constrained machines by cutting tubing runs and wiring complexity. Remember that the built-in 5/2 valve routes air but does not hold the load without live pressure; for true load-holding, select the SAIL lock or BSAI clamp-lock cylinder. For stroke lengths of 300mm or more, add an external guide to prevent excessive side-loading on the rod.
When ordering a replacement, verify the 32mm bore, 80mm stroke, 1/4" valve port, AC110V coil voltage, terminal electrical entry, PT tapered threads, and the -S magnet for CMSE/DMSE sensors.
Quick checklist
The 32mm bore generates 402N push force at 0.5 MPa and 724N at 0.9 MPa. The built-in 4M210-08 5/2 valve provides an effective area of 16.0 mm2 (Cv 0.89) with a maximum frequency of 5 cycles per second.
Yes. The factory setting retracts the rod when the AC110V coil is energised, but you can reconfigure it to extend-when-energised by repositioning the valve. This self-contained design means no separate remote valve is needed.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.