The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF40X100S-06E is a genuine double-acting ISO 15552 cylinder with a Ø40mm bore, 100mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF40X100S-06E is a double-acting ISO 15552 profile cylinder featuring an integrated 4M210-06 5/2 solenoid valve. This specific SKU is configured with a 1/8" PT valve port offering a 14.0 mm2 effective area (Cv 0.78), paired with a PT1/8 cylinder port and an O8 x O5 PU tube linking the manifold block. Driven by an AC24V terminal entry coil drawing 3.5 VA, it activates in 0.05 s or less under IP65 protection. While the bare cylinder rates to 1.0 MPa, the built-in valve limits the practical operating pressure to 0.15-0.8 MPa.
Generating 628 N of push force at 0.5 MPa, this self-switching unit eliminates the need for remote plumbing. Out of the box, the factory setting retracts the piston rod when the coil is energised; you can reconfigure it to extend-when-energised simply by repositioning the valve. The carbon steel piston rod includes a magnet (-S) for position sensing with AirTAC CMSE reed or DMSE electronic switches.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF40X100S-06E |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø40 mm |
| Stroke | 100 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/4 |
| Rod thread | M12×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC24V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 628 N | 528 N |
| 0.7 MPa | 880 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 40×100 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| E | Coil voltage AC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machine layouts where running separate valve tubing is impractical, letting one AC24V signal drive the cylinder directly at the station.
Provides 628 N of push force in a tight footprint, using the integrated 4M210 valve to eliminate external pneumatic plumbing panels.
The included magnet works seamlessly with AirTAC CMSE and DMSE switches for precise end-of-stroke detection in automated handling.
Choose this 40mm bore if your application requires around 628 N of push force at 0.5 MPa. If you need less force, stepping down to a 32mm bore yields 402 N; stepping up to a 50mm bore provides 982 N. The SAIF series excels in decentralized installations across large machines, where routing separate valve tubing is costly or panel space is tight. A single AC24V coil signal drives the cylinder directly.
For load holding, note that the 5/2 valve routes air but does not lock the piston; the variable air cushions only decelerate near stroke ends. For true mechanical holding, consider the SAIL lock series. When ordering a replacement, verify the 40mm bore, 100mm stroke, 06 (1/8") valve port, PT thread, AC24V voltage, terminal entry, and the -S magnet requirement.
Quick checklist
The 40mm bore generates 628 N of push force and 528 N of pull force at 0.5 MPa. The built-in 4M210-06 valve has an effective area of 14.0 mm2 (Cv 0.78).
By factory default, the 5/2 valve retracts the rod when the AC24V coil is energised. You can reconfigure it to extend-when-energised by physically repositioning the valve on the manifold block.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.