verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC SAIF Series · ISO 15552 Cylinder with Valve

Airtac SAIF Series Standard Cylinder with Valve SAIF40X150S-06E

The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF40X150S-06E is a genuine double-acting ISO 15552 cylinder with a Ø40mm bore, 150mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.

  • BoreØ40 mm
  • Stroke150 mm
  • Built-in valve4M210-06
  • Valve port1/8"
  • CoilAC24V
  • EntryTerminal
$106.30 $113.80Save 6% Usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac SAIF Series Standard Cylinder with Valve SAIF40X150S-06E

The AirTAC SAIF40X150S-06E is a double-acting profile cylinder with a built-in 4M210-06 5/2 solenoid valve, offering a Cv of 0.78. Driven by an AC24V terminal coil drawing 3.5 VA, it responds in 0.05s. The integrated valve manages airflow through a PT1/8 port via an O8xO5 PU tube, distinguishing it from the cylinder's own PT1/4 port. Because the valve operates at 0.15-0.8 MPa, this defines the practical working range for the assembly, despite the cylinder body rating of 1.0 MPa. At 0.5 MPa it delivers 628N push force.

Factory-set to retract the rod when energised, the valve can be repositioned to extend on signal. This self-contained design eliminates remote valves and extra tubing, making it perfect for decentralized machine layouts. The -S magnet supports CMSE reed and DMSE electronic sensors for precise positioning.

Airtac SAIF Series Standard Cylinder with Valve SAIF40X150S-06E Technical Specifications

ModelAirtac SAIF Series Standard Cylinder with Valve SAIF40X150S-06E
SeriesSAIF ISO 15552 cylinder with valve
Bore sizeØ40 mm
Stroke150 mm
Acting typeDouble acting, self-valved
Cylinder portG1/4
Rod threadM12×1.25
PU tubeØ8 × Ø5
Built-in valve4M210-06 (5/2)
Valve flow14.0 mm² (Cv 0.78)
Max frequency5 cycle/sec
Coil voltageAC24V · AC 3.5 VA
Electrical entryTerminal · IP65 · B class
Response time0.05 s and below
Operating pressure0.15 – 0.8 MPa (valve limit)
Speed range30 – 800 mm/s

The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.

Theoretical Output Force (Ø40mm)

PressurePush forcePull force
0.5 MPa628 N528 N
0.7 MPa880 N

Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.

Model Code: Airtac SAIF Series Standard Cylinder with Valve SAIF40X150S-06E

SAIFISO 15552 cylinder with built-in 4M valve.
40×150Bore × stroke in mm.
-06Valve port 1/8" → 4M210-06.
ECoil voltage AC24V.
I / (blank)Terminal electrical entry.

SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).

Where the Airtac SAIF Series Standard Cylinder with Valve SAIF40X150S-06E Is Used

factory

Decentralized Assembly Stations

Eliminates the need to run long air lines from a central manifold, using the integrated 4M210 valve to control the 40mm bore directly at the point of operation.

settings_input_component

Compact Electronics Handling

The AC24V coil offers safe low-voltage actuation for sensitive environments, while the self-contained valve architecture saves valuable panel space.

precision_manufacturing

Sensor-Ready Positioning

Equipped with a -S magnet for CMSE and DMSE switches, allowing precise end-of-stroke detection in automated clamping and lifting routines.

Is the Airtac SAIF Series Standard Cylinder with Valve SAIF40X150S-06E the Right Choice?

Select this 40mm bore when 32mm lacks thrust (402N at 0.5MPa) or 50mm is excessive (982N at 0.5MPa). The built-in 4M210-06 valve simplifies installation, removing the need for a separate panel valve and saving wiring effort across decentralized stations. With an AC24V terminal connection, ensure your control system matches this low-voltage coil. For load-holding, note that the 5/2 valve routes air but does not lock; consider SAIL for positive holding. This 150mm stroke is within standard limits, but always verify guide clearances for side loads. Replacement requires matching bore, stroke, PT1/8 valve port, AC24V voltage, PT thread, and the -S magnet.

Quick checklist

  • ✓ Force at 0.15–0.8 MPa
  • ✓ Coil voltage matches panel
  • ✓ Terminal vs grommet entry
  • ✓ Retract- or extend-when-energised
  • ✓ Load-holding → SAIL / BSAI
Ask an Engineer

Airtac SAIF Series Standard Cylinder with Valve SAIF40X150S-06E FAQ

The 40mm bore generates 628N push and 528N pull force at 0.5 MPa. The built-in 4M210-06 valve has an effective area of 14.0 mm2 (Cv 0.78) and a maximum frequency of 5 cycles/sec.

Yes. The factory setting retracts the rod when the AC24V coil is energised, but the 5/2 valve can be repositioned to extend the rod upon energisation. This self-contained switching removes the need for a separate remote valve.

Related AirTAC Cylinders & Valves

Request a Quote for Airtac SAIF Series Standard Cylinder with Valve SAIF40X150S-06E

Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for SAIF40X150S-06E and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.