The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF40X150S-08A is a genuine double-acting ISO 15552 cylinder with a Ø40mm bore, 150mm stroke and a built-in 4M210-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF40X150S-08A is a double-acting ISO 15552 profile cylinder that integrates a 4M210-08 5/2 solenoid valve directly onto its manifold. This specific build features a 1/4" valve port yielding a 16.0 mm2 flow (Cv 0.89), paired with an AC220V terminal entry coil that draws 3.5 VA and responds in 0.05 s. The cylinder bore is 40 mm, generating 628 N of push force at 0.5 MPa. Because the valve operates at 0.15-0.8 MPa, this defines the practical working range for the assembled unit, even though the bare cylinder rates to 1.0 MPa.
By switching itself from a single coil signal, this actuator eliminates remote plumbing and saves panel space, making it ideal for decentralized machine stations. The manifold connects to the cylinder via O8 x O5 PU tubing, while the factory default setting retracts the rod when the coil is energised; this can be reconfigured to extend-when-energised simply by repositioning the valve. The -S suffix denotes an integrated magnet for position sensing with AirTAC CMSE (reed) or DMSE (electronic) switches.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF40X150S-08A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø40 mm |
| Stroke | 150 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/4 |
| Rod thread | M12×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-08 (5/2) |
|---|---|
| Valve flow | 16.0 mm² (Cv 0.89) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 628 N | 528 N |
| 0.7 MPa | 880 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 40×150 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M210-08. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Perfect for large machines with multiple nodes, eliminating long tubing runs by switching locally via the AC220V terminal coil.
Fits into tight machinery envelopes where a separate 4M210 valve and manifold block would consume too much mounting space.
The integrated -S magnet provides precise end-of-stroke detection for CMSE and DMSE switches in automated clamping.
Choose this 40 mm bore when you need 628 N push force at 0.5 MPa; stepping down to a 32 mm bore drops the push force to 402 N, while a 50 mm bore increases it to 982 N. The self-valved SAIF architecture is superior to a separate cylinder and remote valve when wiring and air tubing runs are costly or space-constrained. This model uses an AC220V terminal connection with PT tapered threads. If your application requires holding the load without live air pressure, note that the 5/2 valve routes air but does not lock the piston; consider an AirTAC SAIL lock cylinder instead. For this 150 mm stroke, ensure adequate guide support to prevent side-loading. Replacement exact match: 40 mm bore, 150 mm stroke, 1/4" valve port, AC220V, terminal entry, PT thread, with magnet (-S).
Quick checklist
The 40 mm bore generates 628 N push and 528 N pull force at 0.5 MPa. The integrated 4M210-08 5/2 valve has an effective orifice of 16.0 mm2 (Cv 0.89) and supports a maximum frequency of 5 cycles per second.
No, the 4M210-08 valve is built into the manifold, requiring only the AC220V electrical signal to switch. The factory default retracts the rod when energised, but it can be reconfigured to extend-when-energised by repositioning the valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.