The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF40X225-06B is a genuine double-acting ISO 15552 cylinder with a Ø40mm bore, 225mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF40X225-06B is a double-acting ISO 15552 profile cylinder featuring an integrated 4M210-06 5/2 solenoid valve. This built-in valve provides a Cv of 0.78 (14.0 mm2 orifice) and mounts directly via a manifold block using O8 x O5 PU tubing, eliminating the need for remote plumbing. Equipped with a DC24V terminal entry coil, it consumes 3.0 W, features IP65 protection, and activates in 0.05 s or less. The cylinder bore is 40 mm, generating 628 N of push force at 0.5 MPa, while the carbon steel rod and PT1/8 cylinder ports ensure robust pneumatic connections.
Because the cylinder body rates to 1.0 MPa but the internal pilot valve operates specifically within 0.15-0.8 MPa, the practical working pressure for this assembled unit is 0.15-0.8 MPa. By default, the factory setting retracts the piston rod when the coil is energised; however, you can reconfigure it to extend-when-energised simply by repositioning the valve. This self-switching design requires only one coil signal to drive the motion, making it highly effective for decentralized installation across large machines where panel space and tubing runs are limited.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF40X225-06B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø40 mm |
| Stroke | 225 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/4 |
| Rod thread | M12×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 628 N | 528 N |
| 0.7 MPa | 880 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 40×225 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large automated machinery where running individual valve lines back to a central panel is costly, this self-valved cylinder operates independently from a single DC24V signal.
The integrated 4M210-06 valve manifold saves valuable panel and tubing space, delivering 528 N of pull force at 0.5 MPa for compact clamping fixtures.
Perfect for upgrading existing lines where adding external pneumatic plumbing is difficult, this unit provides a complete actuation package with a 1/8" valve port and PT1/8 cylinder connection.
Choose this 40 mm bore when an application requires around 628 N of push force at 0.5 MPa; if you need less force, step down to the 32 mm bore (402 N push at 0.5 MPa), or move up to the 50 mm bore (982 N push at 0.5 MPa) for higher loads. The integrated 4M210-06 valve with a 1/8" port offers a 5 cycle/sec max frequency, making it ideal for space-tight machines where running separate valve tubing is costly or impractical. With a 225 mm stroke, ensure you provide adequate guidance to prevent excessive side-loading on the carbon steel rod.
This SAIF unit switches itself from one DC24V terminal signal, entirely removing the need for a separate remote valve. Remember that the 5/2 valve routes air but does not lock the load mechanically; if your application requires true position holding without live pressure, consider the AirTAC SAIL lock or BSAI clamp-lock series instead. When replacing, match the 40 mm bore, 225 mm stroke, 06 (1/8") valve port, DC24V voltage, terminal entry, PT thread, and standard non-magnet configuration.
Quick checklist
At an operating pressure of 0.5 MPa, this 40 mm bore cylinder provides 628 N of push force and 528 N of pull force. The practical working pressure for the assembled unit is 0.15-0.8 MPa, limited by the built-in 4M210-06 valve.
Yes. By default, the factory setting retracts the rod when the DC24V coil is energised. You can reconfigure it to extend-when-energised by repositioning the 5/2 valve on the manifold block, eliminating the need for a separate remote valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.