The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF40X450-06A is a genuine double-acting ISO 15552 cylinder with a Ø40mm bore, 450mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF40X450-06A is a double-acting ISO 15552 profile cylinder paired with a built-in 4M210-06 5/2 solenoid valve. Driven by an AC220V terminal connection coil consuming 3.5 VA, it responds in 0.05s. The integrated valve manages a 14.0mm2 orifice (Cv 0.78) using internal pilot pressure, routing air through PU tubing (O8xO5) to the cylinder's PT1/8 ports. Because the valve body limits pressure, the practical working range is 0.15-0.8 MPa despite the cylinder body rating of 1.0 MPa.
At 0.5 MPa it delivers 628N push and 528N pull force, scaling to 1130N push at 0.9 MPa. Factory-set to retract the rod when energized, the valve can be repositioned to extend-when-energized if your logic requires it. By switching itself from one coil signal, this unit eliminates remote plumbing and saves panel space for decentralized machine stations.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF40X450-06A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø40 mm |
| Stroke | 450 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/4 |
| Rod thread | M12×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 628 N | 528 N |
| 0.7 MPa | 880 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 40×450 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines with multiple stations, using the built-in 4M210 valve to actuate the 40mm bore locally without running long pneumatic lines back to a central manifold.
The 450mm stroke handles extended push-off or sorting tasks on conveyors, while the integrated AC220V valve ensures rapid 0.05s switching right at the action point.
Eliminates the need for a separate remote valve bank and mounting brackets, saving critical panel and floor space in compact automated equipment.
Select this 40mm bore when 32mm (402N push at 0.5MPa) lacks power but 50mm (982N push) is oversized. The 450mm stroke suits long-travel handling, but because it exceeds 300mm you must account for rod side-loads and use external guide rails to prevent binding. Choose this self-valved SAIF over a separate cylinder and remote valve when decentralizing stations across a large machine, as it cuts tubing runs and wiring complexity.
This unit uses a 4M210-06 valve (PT1/8 valve port) with an AC220V terminal entry coil. The carbon steel rod and PT tapered threads are standard. It lacks a magnet for sensors; add -S for CMSE reed or DMSE electronic solid-state switches. Remember the 5/2 valve routes air but does not lock the load—use AirTAC SAIL for holding requirements.
Quick checklist
The 40mm bore generates 628N push and 528N pull force at 0.5 MPa, reaching 1130N push at 0.9 MPa. The built-in 4M210-06 5/2 valve has a 14.0mm2 effective area (Cv 0.78) and supports a maximum frequency of 5 cycles per second.
No, the 5/2 valve routes air but does not lock the load; use SAIL for holding. This model uses an AC220V terminal entry coil (3.5 VA, IP65). Factory-set to retract when energized, you can reposition the valve to extend-when-energized.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.