The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF40X50S-06B is a genuine double-acting ISO 15552 cylinder with a Ø40mm bore, 50mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF40X50S-06B is a double-acting ISO 15552 profile cylinder with an integrated 4M210-06 5/2 solenoid valve, yielding a 14.0 mm2 effective area (Cv 0.78). Driven by a DC24V terminal coil drawing 3.0 W, it switches itself in 0.05 s without remote plumbing. The cylinder body rates to 1.0 MPa, but the internal pilot valve operates at 0.15-0.8 MPa, setting the practical working range for the assembled unit. A carbon steel rod and PT1/8 cylinder port are standard.
It delivers 628 N push and 528 N pull at 0.5 MPa. The manifold uses O8 x O5 PU tubing, and the valve port code 06 (1/8") differs from the cylinder port. Factory-set to retract when energised, the valve can be repositioned to extend on signal. The -S magnet supports CMSE reed and DMSE electronic sensors for position feedback.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF40X50S-06B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø40 mm |
| Stroke | 50 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/4 |
| Rod thread | M12×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 628 N | 528 N |
| 0.7 MPa | 880 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 40×50 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates remote valve islands by switching locally from a single DC24V signal, reducing tubing across large factory layouts.
Provides 628 N push force at 0.5 MPa in tight spaces where running separate valve plumbing is mechanically impractical.
The -S magnet pairs with CMSE and DMSE switches to confirm clamping or release positions in automated processing.
Choose this 40mm bore when a 32mm bore (402 N push at 0.5 MPa) is insufficient, but a 50mm bore (982 N) is oversized. The self-valved SAIF excels in decentralized stations by eliminating separate valve islands and long tubing runs, saving panel space. A DC24V terminal entry suits standard low-voltage control systems. If the load must hold position without live pressure, select a SAIL lock cylinder instead, as the 5/2 valve only routes air and does not brake. For replacement, match the 50mm stroke, 4M210-06 valve, DC24V terminal coil, PT thread, and -S magnet.
Quick checklist
At 0.5 MPa, this 40mm bore cylinder generates 628 N of push force and 528 N of pull force. The practical operating pressure is 0.15-0.8 MPa.
The integrated 5/2 valve is powered by a DC24V terminal coil (3.0 W). Factory-set to retract the rod when energised, it can be repositioned to extend on signal, eliminating the need for a separate remote valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.