The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF40X600S-08A is a genuine double-acting ISO 15552 cylinder with a Ø40mm bore, 600mm stroke and a built-in 4M210-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF40X600S-08A is a double-acting ISO 15552 profile cylinder featuring a built-in 4M210-08 5/2 solenoid valve. Equipped with a magnetic piston (-S) for CMSE reed and DMSE electronic sensors, it delivers 628N of push force at 0.5 MPa. The integrated valve offers a 16.0mm2 orifice (Cv 0.89) and operates at 30-800mm/s. Because the manifold uses an O8xO5 PU tube to bridge the valve and cylinder, the valve port (1/4) is intentionally distinct from the cylinder port (1/4).
This assembly is driven by an AC220V terminal coil consuming 3.5 VA, featuring IP65 protection and a 0.05s activation time. While the cylinder body rates to 1.0 MPa, the internal pilot valve limits the practical working range to 0.15-0.8 MPa. By default, the piston rod retracts when the coil is energised, but you can reconfigure it to extend-when-energised simply by repositioning the valve. This self-switching design eliminates remote valves, saving panel space and tubing across decentralized machine stations.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF40X600S-08A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø40 mm |
| Stroke | 600 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/4 |
| Rod thread | M12×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-08 (5/2) |
|---|---|
| Valve flow | 16.0 mm² (Cv 0.89) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 628 N | 528 N |
| 0.7 MPa | 880 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 40×600 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M210-08. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates the need for a central valve bank by driving the 600mm stroke directly from a local AC220V signal, reducing machine tubing complexity.
Provides 628N of push force at 0.5MPa to deflect packages, utilizing the built-in 4M210 valve for rapid 5 cycle/sec operation.
Integrates the valve and cylinder into one envelope, fitting easily into tight retrofit spaces where running separate valve tubing is costly.
Choose this 40mm bore when a 32mm cylinder (402N push at 0.5MPa) lacks thrust, but a 50mm bore (982N push) is oversized. The 600mm stroke requires external guide support to prevent rod side-loading and premature seal wear. Since the stroke is under the 1200mm standard maximum, it ships as a standard configuration.
A self-valved SAIF unit excels over a separate cylinder and remote valve by cutting wiring and plumbing complexity. To replace this assembly, match the 40mm bore, 600mm stroke, 1/4 valve port, AC220V terminal coil, PT thread, and -S magnet. Remember that the 5/2 valve routes air but does not lock the load; for position holding, consider an AirTAC SAIL pneumatic lock cylinder.
Quick checklist
The 40mm bore generates 628N push and 528N pull force at 0.5MPa. The built-in 4M210-08 5/2 valve has a 16.0mm2 effective area (Cv 0.89) and supports a maximum frequency of 5 cycles per second.
No, the 5/2 valve routes air but does not lock the load pneumatically. By factory default, the rod retracts when the AC220V coil is energised, but you can reposition the valve to extend-when-energised. For true load holding, use an AirTAC SAIL cylinder.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.