The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF50X125-08A is a genuine double-acting ISO 15552 cylinder with a Ø50mm bore, 125mm stroke and a built-in 4M210-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF50X125-08A is a double-acting ISO 15552 profile cylinder featuring a built-in 4M210-08 5/2 solenoid valve. Driven by an AC220V terminal coil drawing 3.5 VA, it delivers a Cv of 0.89 with a 0.05s activation time. Because the cylinder body rates to 1.0 MPa but the integrated valve operates at 0.15-0.8 MPa, the practical working range for this assembled unit is 0.15-0.8 MPa. It generates 982N of push force at 0.5 MPa.
This decentralized design eliminates the need for a separate remote valve, reducing plumbing and panel space. The manifold connects to the cylinder via O8xO5 PU tubing, distinguishing the 1/4" valve port from the cylinder's own 1/4" port. Factory-set to retract the rod when energized, the valve can be repositioned to extend on signal. The standard carbon steel rod and PT tapered threads ensure durable, leak-free pneumatic performance.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF50X125-08A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø50 mm |
| Stroke | 125 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/4 |
| Rod thread | M16×1.5 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-08 (5/2) |
|---|---|
| Valve flow | 16.0 mm² (Cv 0.89) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 982 N | 825 N |
| 0.7 MPa | 1374 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 50×125 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M210-08. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates remote valve plumbing, allowing independent control of multiple clamping points across a large machine layout.
The integrated 4M210 valve saves valuable panel space, fitting high-force actuation into compact equipment frames.
Ideal for upgrading existing lines where routing new air tubing back to a central manifold is prohibitively expensive.
Choose this 50mm bore when you need roughly 982N push force at 0.5 MPa, stepping up from a 40mm bore (628N) or down from a 63mm bore (1559N). A self-valved SAIF excels in space-tight machines or decentralized stations where running tubing back to a main valve manifold is costly. The AC220V terminal connection suits standard plant power, and because no -S magnet is specified here, add it if you require CMSE reed or DMSE electronic sensors for position feedback. For load-holding, note that the 5/2 valve routes air but does not lock the piston; consider a SAIL lock cylinder for braking applications. Replacement requires matching the 50mm bore, 125mm stroke, 08 valve port, AC220V voltage, terminal entry, and PT threads.
Quick checklist
At 0.5 MPa, this 50mm bore cylinder provides 982N of push force and 825N of pull force. The built-in 4M210-08 valve has an effective area of 16.0 mm2 (Cv 0.89) and supports a maximum frequency of 5 cycles per second.
The integrated 4M210 5/2 valve lets the cylinder switch itself from one AC220V coil signal, drastically reducing tubing and panel space. It is factory-set to retract when energized but can be reconfigured to extend on signal by repositioning the valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.