The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF50X250SFA-08B is a genuine double-acting ISO 15552 cylinder with a Ø50mm bore, 250mm stroke and a built-in 4M210-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF50X250S-08B is a double-acting ISO 15552 profile cylinder featuring a built-in 4M210-08 5/2 solenoid valve. It delivers a push force of 982N at 0.5 MPa and utilizes a 16.0 mm2 orifice (Cv 0.89). Equipped with a DC24V terminal coil drawing 3.0 W, it achieves IP65 protection and a 0.05 s response time. The integrated manifold connects via an O8 x O5 PU tube, while the valve uses a 1/4" port and the cylinder body uses a 1/4" PT port.
Because the cylinder rates to 1.0 MPa but the integrated valve operates at 0.15-0.8 MPa, the practical working range for this assembled unit is 0.15-0.8 MPa. By default, the piston rod retracts when the coil is energized, but you can reconfigure it to extend-when-energized simply by repositioning the valve. This self-contained design eliminates the need for a separate remote valve, saving panel space and tubing, making it ideal for decentralized machine stations. The -S magnet works with AirTAC CMSE (reed) and DMSE (electronic) sensors.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF50X250SFA-08B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø50 mm |
| Stroke | 250 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/4 |
| Rod thread | M16×1.5 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-08 (5/2) |
|---|---|
| Valve flow | 16.0 mm² (Cv 0.89) |
| Max frequency | 5 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 982 N | 825 N |
| 0.7 MPa | 1374 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 50×250 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M210-08. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Perfect for large machines where running individual valve lines is costly; the integrated 4M210 valve handles switching directly at the cylinder.
Saves valuable panel space by eliminating remote valve banks, driving 982N of force at 0.5 MPa with a direct DC24V signal.
Easily add self-switching actuation to existing lines without re-plumbing central manifolds, utilizing the ISO 15552 mounting interface.
Choose this self-valved SAIF unit when decentralized installation matters: it switches itself from one coil signal, removing the need to run long valve tubing back to a central manifold. If your application requires less force, stepping down to a 40 mm bore yields 628N push at 0.5 MPa; if you need more power, a 63 mm bore provides 1559N. Remember that the built-in 5/2 valve routes air but does not hold the load without live pressure—use a SAIL lock cylinder for true position holding. Since the stroke is 250 mm, ensure adequate guiding to prevent side-load wear on the rod seals.
When ordering a replacement, verify the 50 mm bore, 250 mm stroke, 1/4" valve port, DC24V voltage, terminal entry, PT thread, and the -S magnet. The standard carbon steel rod and FA mounting accessory are included.
Quick checklist
The 50 mm bore produces 982N push force at 0.5 MPa and 1767N at 0.9 MPa. The built-in 4M210-08 valve has a 16.0 mm2 orifice with a Cv of 0.89.
No, the integrated 5/2 valve switches the cylinder directly from a DC24V signal. By factory default, the rod retracts when energized, but you can reposition the valve to extend-when-energized.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.