The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF50X500S-08B is a genuine double-acting ISO 15552 cylinder with a Ø50mm bore, 500mm stroke and a built-in 4M210-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF50X500S-08B is a double-acting ISO 15552 profile cylinder equipped with a built-in 4M210-08 5/2 solenoid valve, providing a Cv of 0.89. Driven by a DC24V terminal coil consuming 3.0 W, it eliminates the need for a remote valve island. The integrated manifold uses O8 x O5 PU tubing to bridge the valve and cylinder, drastically reducing plumbing across decentralized machine stations. Because the valve limits the system, the practical operating pressure is 0.15-0.8 MPa, despite the cylinder body rating of 1.0 MPa.
Delivering 982 N of push force at 0.5 MPa, this 50 mm bore unit includes an -S magnet for CMSE reed and DMSE electronic sensors. By default, the piston rod retracts when the coil is energised, but you can reconfigure it to extend-when-energised by repositioning the valve. The carbon steel rod and tapered PT threads ensure robust, leak-free operation.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF50X500S-08B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø50 mm |
| Stroke | 500 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/4 |
| Rod thread | M16×1.5 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-08 (5/2) |
|---|---|
| Valve flow | 16.0 mm² (Cv 0.89) |
| Max frequency | 5 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 982 N | 825 N |
| 0.7 MPa | 1374 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 50×500 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M210-08. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large-scale factory equipment where routing individual valve lines is costly, letting each cylinder switch itself via a single DC24V signal.
Provides 982 N of push force at 0.5 MPa for diverting or sorting items on a conveyor line, with the 5/2 valve ensuring a fast 5 cycles per second.
Perfect for upgrading older machines where panel space is full, as the built-in valve and manifold remove the need for external pneumatic plumbing.
Choose this self-valved SAIF model when installing decentralized actuators across large machines, as it saves significant panel space and wiring compared to running separate cylinder lines to a remote valve. If your application requires less force, stepping down to a 40 mm bore yields 628 N push at 0.5 MPa; for heavier loads, a 63 mm bore provides 1559 N. For this 500 mm stroke, adding an external guide is recommended to prevent excessive side-load on the rod seals.
To replace this unit, match the 50 mm bore, 500 mm stroke, 1/4" valve port (08 code), DC24V terminal coil, and PT thread. Remember that the 5/2 valve routes air but does not lock the load mechanically—use an AirTAC SAIL lock cylinder if position holding without live pressure is required.
Quick checklist
The 50 mm bore cylinder generates 982 N of push force at 0.5 MPa. The integrated 4M210-08 5/2 valve has an effective area of 16.0 mm2 (Cv 0.89) and supports a maximum frequency of 5 cycles per second.
It uses a DC24V terminal coil (3.0 W, IP65) to switch the cylinder directly. By factory default, energising the coil retracts the rod, but this can be reconfigured to extend-when-energised by repositioning the valve. This eliminates the need for a separate remote valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.