The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF50X80S-06A is a genuine double-acting ISO 15552 cylinder with a Ø50mm bore, 80mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF50X80S-06A is a double-acting ISO 15552 profile cylinder equipped with a built-in 4M210-06 5/2 solenoid valve. Delivering a Cv of 0.78 and a 14.0 mm2 effective area, this integrated assembly switches itself from a single AC220V terminal coil signal. It generates 982N of push force at 0.5 MPa. Because the cylinder body rates to 1.0 MPa but the internal pilot valve operates at 0.15-0.8 MPa, the practical working range for the assembled SAIF unit is 0.15-0.8 MPa.
By default, the factory setting retracts the piston rod when the coil is energised, and you can reconfigure it to extend-when-energised by repositioning the valve. The manifold connects to the 1/4 inch cylinder port using O8xO5 PU tubing, while the valve itself features a PT 1/8 port. This decentralized design eliminates remote plumbing, and the included -S magnet works seamlessly with CMSE reed and DMSE electronic sensors for position feedback.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF50X80S-06A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø50 mm |
| Stroke | 80 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/4 |
| Rod thread | M16×1.5 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 982 N | 825 N |
| 0.7 MPa | 1374 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 50×80 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates the need for a remote valve island on large machines by driving the 50mm bore directly from its built-in 4M210 valve, saving significant panel and plumbing space.
Ideal for compact equipment where running separate valve tubing is costly, leveraging the integrated AC220V terminal coil and short PU manifold for rapid 0.05 s switching.
Perfect for upgrading existing ISO 15552 interchangeable setups where decentralized control is preferred, requiring only a single electrical signal instead of complex air lines.
Choose this 50mm bore when an application requires around 982N push force at 0.5 MPa; stepping down to a 40mm bore yields 628N, while a 63mm bore provides 1559N. A self-valved SAIF50X80S-06A beats a separate cylinder and remote valve in space-tight machines by minimizing tubing and panel footprint. The AC220V terminal coil draws 3.5 VA, features IP65 protection, and activates in 0.05 s or less. Remember that the 5/2 valve routes air and is not a lock; the air cushion only decelerates near stroke end. For load-holding requirements, consider the SAIL lock or BSAI clamp-lock series.
When ordering a replacement, verify the 50mm bore, 80mm stroke, 06 (1/8 inch) valve port, AC220V voltage, terminal entry, PT thread, and the -S magnet. The standard carbon steel rod and extruded aluminum barrel ensure durability across 30-800 mm/s operating speeds.
Quick checklist
The 50mm bore generates 982N push force and 825N pull force at 0.5 MPa. The built-in 4M210-06 valve provides a 14.0 mm2 effective area (Cv 0.78) and supports a maximum frequency of 5 cycles per second.
Yes. By default, the factory setting retracts the rod when the AC220V coil is energised. You can reconfigure it to extend-when-energised by physically repositioning the 5/2 valve on the manifold, eliminating the need for a separate remote valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.