The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF63X1000S-10B is a genuine double-acting ISO 15552 cylinder with a Ø63mm bore, 1000mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF63X1000S-10B is a double-acting ISO 15552 profile cylinder with a built-in 4M310-10 5/2 solenoid valve, delivering a 1.68 Cv flow. Driven by a DC24V terminal entry coil drawing 3.0 W, it includes a magnet for CMSE reed and DMSE electronic sensors. The cylinder body rates to 1.0 MPa, but because the internal piloted valve operates at 0.15-0.8 MPa, the practical working range for this assembled unit is 0.15-0.8 MPa.
It delivers 1559N of push thrust at 0.5 MPa. The manifold connects to the cylinder via PU tubing (O10 x O6.5). Factory-set to retract when energised, the valve can be repositioned to extend on signal. It eliminates remote valves, saving panel space for decentralized machine stations.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF63X1000S-10B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 1000 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M16×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 63×1000 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates the need for a remote valve bank on large machines by switching directly from a single DC24V signal, drastically reducing plumbing.
Provides 1559N push force at 0.5 MPa for pushing or diverting products on long 1000mm strokes where guided movement is ensured.
Ideal for upgrading existing lines where adding external valve tubing is difficult, as the built-in valve and manifold save panel space.
Choose this 63mm bore when 50mm falls short (982N push at 0.5 MPa) and 80mm is excessive (2513N). The 1000mm stroke is substantial; always use a guide to prevent rod side-loading and premature seal wear. The integrated 4M310-10 valve means no separate valve bank is needed—perfect when running tubing across a large machine is costly. The DC24V terminal coil offers IP65 protection and a 0.05s response. Remember, the 5/2 valve routes air but is not a lock; for load-holding, select a SAIL lock cylinder. Replacement match: 63mm bore, 1000mm stroke, PT3/8 cylinder port, 3/8 valve port, DC24V, terminal entry, PT thread, with magnet.
Quick checklist
At 0.5 MPa it provides 1559N push and 1402N pull force. The built-in 4M310-10 5/2 valve has an effective area of 30.0 mm2 (Cv 1.68) and a max frequency of 4 cycles/sec.
No, it switches itself using the integrated 4M310 valve driven by a DC24V (3.0W) terminal coil. By default the rod retracts when energised, but you can reposition the valve to extend-when-energised.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.