The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF63X100S-10A is a genuine double-acting ISO 15552 cylinder with a Ø63mm bore, 100mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF63X100S-10A is a double-acting ISO 15552 profile cylinder featuring an integrated 4M310-10 5/2 solenoid valve. This built-in valve delivers a 30.0 mm2 effective area (Cv 1.68) and shifts via an AC220V terminal entry coil drawing 3.5 VA. Because the cylinder rates to 1.0 MPa but the valve operates at 0.15-0.8 MPa, the practical working range for this assembled unit is 0.15-0.8 MPa.
It delivers 1559 N of push force at 0.5 MPa and includes a magnet for position sensing with CMSE reed or DMSE electronic switches. The manifold feeds the PT3/8 cylinder ports via PU tubing, meaning the valve port differs from the cylinder port. Factory set to retract the rod when the coil energizes, you can reposition the valve to extend-when-energized. It eliminates remote plumbing for decentralized machine stations.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF63X100S-10A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 100 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M16×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 63×100 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines where running individual valve tubing back to a central manifold is costly and space-prohibitive.
Provides robust 1559 N push force at 0.5 MPa for clamping, pressing, and part handling directly at the workstation.
Simplifies machine upgrades by bolting a self-contained air logic unit onto the ISO 15552 mounting interface.
Choose this 63 mm bore when 50 mm (982 N push at 0.5 MPa) is too weak and 80 mm (2513 N push at 0.5 MPa) is oversized. A self-valved SAIF beats a separate cylinder plus remote valve by cutting panel space, wiring, and tubing runs across large machines. This model uses an AC220V terminal coil with PT threads; specify the exact bore, 100 mm stroke, 10 valve port, voltage, and -S magnet for replacements. For stroke lengths of 300 mm or more, add external guide supports to prevent rod side-loading. Note that the 5/2 valve routes air but does not lock the load; use a SAIL cylinder for mechanical holding.
Quick checklist
The built-in 4M310-10 valve has an effective area of 30.0 mm2 (Cv 1.68). While the cylinder body rates to 1.0 MPa, the valve limits the practical operating pressure range to 0.15-0.8 MPa.
No, the built-in 5/2 valve routes air but does not mechanically lock the piston. By default, the rod retracts when the AC220V coil energizes, but you can reposition the valve to extend-when-energized.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.