The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF63X100S-10B is a genuine double-acting ISO 15552 cylinder with a Ø63mm bore, 100mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF63X100S-10B is a double-acting ISO 15552 profile cylinder equipped with a built-in 4M310-10 5/2 solenoid valve, delivering a 30 mm2 effective orifice (Cv 1.68). Driven by a DC24V terminal coil drawing 3.0 W, it achieves IP65 protection and a 0.05 s activation time. The integrated manifold connects via O10 x O6.5 PU tubing, meaning the 3/8 inch valve port and 3/8 inch cylinder port are pre-plumbed directly on the unit.
Because the cylinder body rates to 1.0 MPa but the internal pilot valve operates at 0.15-0.8 MPa, the practical working range for this assembled actuator is 0.15-0.8 MPa. Generating 1559 N of push force at 0.5 MPa, it includes a standard magnet for position sensing with CMSE reed and DMSE solid-state switches. By default, the piston rod retracts when the coil is energised, but you can reconfigure the valve to extend-when-energised by simply repositioning it.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF63X100S-10B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 100 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M16×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 63×100 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large factory layouts where routing individual air lines to a central valve bank is costly, as this cylinder switches itself from one local electrical signal.
Saves valuable panel and footprint space by mounting the 5/2 valve and manifold directly onto the ISO 15552 profile barrel, reducing overall plumbing complexity.
The integrated -S magnet works with CMSE and DMSE sensors to confirm mid-stroke or end-of-stroke positions in automated assembly and handling stations.
Choose this self-valved SAIF unit when you need decentralized actuation across a large machine, eliminating the need to run long valve tubing back to a central panel. If your application requires less force, stepping down to a 50 mm bore yields 982 N of push at 0.5 MPa, whereas moving up to an 80 mm bore provides 2513 N. The built-in 5/2 valve routes air to switch the cylinder from a single coil signal, but note that it does not hold the load without live pressure—use an AirTAC SAIL lock cylinder for true mechanical holding.
When ordering a replacement, verify the 63 mm bore, 100 mm stroke, 3/8 inch valve port, DC24V terminal coil, PT tapered threading, and the -S magnet option. The 4M310 valve allows a maximum frequency of 4 cycles per second, and the cylinder speed ranges from 30-800 mm/s.
Quick checklist
The 63 mm bore generates 1559 N of push force and 1402 N of pull force at 0.5 MPa. The built-in 4M310-10 valve provides a 30 mm2 effective orifice (Cv 1.68) with a maximum operating frequency of 4 cycles per second.
Yes. The factory setting retracts the rod when the DC24V coil is energised, but you can reconfigure it to extend-when-energised by repositioning the 5/2 valve on the manifold block. This eliminates the need for a separate remote valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.