The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF63X125-08A is a genuine double-acting ISO 15552 cylinder with a Ø63mm bore, 125mm stroke and a built-in 4M310-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF63X125-08A is a double-acting ISO 15552 profile cylinder featuring an integrated 4M310-08 5/2 solenoid valve. This built-in valve delivers a 25.0 mm2 effective area (Cv 1.40) and switches via an AC220V terminal connection, drawing 3.5 VA with an IP65 rating and a maximum 0.05 s response time. Because the manifold links the valve to the cylinder using O10 x O6.5 PU tubing, you save panel space and eliminate remote plumbing.
The bare cylinder rates to 1.0 MPa, but the practical operating range for this valved assembly is 0.15-0.8 MPa, yielding a push force of 1559 N at 0.5 MPa and 2182 N at 0.7 MPa. From the factory, the default setting retracts the piston rod when the coil is energised, though you can reposition the valve to extend on signal. The unit uses a carbon steel rod with PT tapered threads, and the cylinder port is 3/8 while the valve port is 1/4.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF63X125-08A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 125 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M16×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-08 (5/2) |
|---|---|
| Valve flow | 25.0 mm² (Cv 1.40) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 63×125 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M310-08. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines with multiple stations, eliminating long air lines by mounting the 4M310 valve directly on the cylinder for localized AC220V control.
Provides robust 1559 N push force at 0.5 MPa to actuate routing gates, with the integrated valve ensuring fast 4 cycle/sec switching without remote plumbing.
Saves valuable panel space by bundling the ISO 15552 actuator and 5/2 valve together, simplifying wiring through the terminal electrical entry.
Choose this 63 mm bore when a 50 mm cylinder lacks thrust, as the 50 mm bore provides 982 N push at 0.5 MPa compared to the 1559 N offered here. Stepping up to an 80 mm bore yields 2513 N at 0.5 MPa if your application demands higher load movement. This self-valved SAIF configuration excels in decentralized stations where running separate valve tubing is costly, as one AC220V coil signal directly drives the actuator.
For replacements, verify the 125 mm stroke, 3/8 cylinder port, 1/4 valve port, AC220V voltage, terminal entry, and PT threads. Note that the 5/2 valve routes air and is not a locking mechanism; if you need true load holding under zero pressure, select an AirTAC SAIL lock cylinder instead. The stroke is under the 1500 mm standard maximum, so no side-load guide is required.
Quick checklist
At 0.5 MPa, this 63 mm bore cylinder generates 1559 N of push force and 1402 N of pull force. The integrated 4M310-08 5/2 valve has an effective area of 25.0 mm2 (Cv 1.40) and supports a maximum frequency of 4 cycles per second.
The factory default setting retracts the piston rod when the AC220V coil is energized. Because it uses a 5/2 pilot valve, you can reconfigure the unit to extend-when-energized simply by repositioning the valve on the manifold block, eliminating the need for a separate remote valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.