The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF63X160-10B is a genuine double-acting ISO 15552 cylinder with a Ø63mm bore, 160mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF63X160-10B is a double-acting ISO 15552 profile cylinder featuring an integrated 4M310-10 5/2 solenoid valve. This built-in valve delivers a 30.0 mm2 effective area (Cv 1.68) and mounts directly via a manifold block using O10 x O6.5 PU tubing. Equipped with a DC24V terminal entry coil consuming 3.0 W, it activates in 0.05 s with an IP65 rating. The cylinder itself features a PT3/8 port and a carbon steel piston rod.
Because the valve operates at 0.15-0.8 MPa, the practical working range for the assembled SAIF unit is 0.15-0.8 MPa, even though the bare cylinder rates to 1.0 MPa. At 0.5 MPa this 63 mm bore generates 1559 N of push force and 1402 N of pull force. By default the rod retracts when the coil is energised, but you can reposition the valve to extend-when-energised. This self-switching design eliminates remote plumbing, saving panel space for decentralized machine stations.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF63X160-10B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 160 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M16×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 63×160 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines with decentralized stations, eliminating long pneumatic tubing runs by switching the cylinder directly at the point of use with a single DC24V signal.
Provides 1559 N of push force at 0.5 MPa in tight spaces where mounting a separate 5/2 valve and manifold would violate the machine envelope.
Perfect for upgrading existing ISO 15552 tooling where adding a remote valve island is too expensive, using the built-in 4M310 valve and O10 x O6.5 PU tubing.
Choose this 63 mm bore when a 50 mm bore (offering 982 N push at 0.5 MPa) is too weak, but an 80 mm bore (2513 N push) is physically oversized. The SAIF63X160-10B excels in decentralized installations where running separate valve tubing is costly, as one DC24V coil signal directly drives the cylinder. The 160 mm stroke falls well below the 1500 mm maximum standard stroke, so no non-standard surcharge applies.
For replacements, verify the 63 mm bore, 160 mm stroke, PT3/8 cylinder port, 10 (3/8") valve port, DC24V voltage, and terminal electrical entry. Note that the integrated 5/2 valve routes air but does not hold the load without live pressure; for true position holding under air loss, consider the SAIL lock series instead. Strokes under 300 mm generally require no auxiliary side-load guides.
Quick checklist
At 0.5 MPa, this 63 mm bore double-acting cylinder generates 1559 N of push force and 1402 N of pull force. The integrated 4M310-10 valve has a 30.0 mm2 orifice (Cv 1.68) to handle the required airflow.
No, the integrated 4M310 5/2 valve controls the cylinder directly from a DC24V terminal coil signal. By factory default, the rod retracts when the coil is energised, but the valve can be repositioned to extend-when-energised.