The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF63X175-10A is a genuine double-acting ISO 15552 cylinder with a Ø63mm bore, 175mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF63X175-10A is a double-acting ISO 15552 profile cylinder featuring a built-in 4M310-10 5/2 solenoid valve. This integrated assembly delivers a Cv of 1.68 and operates on an AC220V terminal coil drawing 3.5 VA. Because the cylinder body rates to 1.0 MPa but the internal pilot valve limits supply pressure, the practical working range for this valved unit is 0.15-0.8 MPa. With a 63mm bore, it generates 1559N of push force at 0.5 MPa.
By default, the piston rod retracts when the coil is energised, though you can reconfigure it to extend-when-energised by repositioning the valve. This decentralized design switches itself from one coil signal, eliminating remote plumbing. The manifold connects the valve to the cylinder using PU tubing (O10 x O6.5), and the valve port (3/8) differs from the cylinder port (3/8). It includes variable air cushions at both ends and operates at speeds of 30-800 mm/s.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF63X175-10A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 175 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M16×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 63×175 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines where running individual valve tubing back to a main manifold is costly, letting each station control itself locally.
Provides 1559N of push force at 0.5 MPa for clamping and pressing tasks in compact automated assembly machinery.
Perfect for upgrading older equipment where adding a separate valve island is impossible due to limited panel and wiring space.
Choose this 63mm bore when 50mm cylinders lack thrust; stepping down to a 50mm bore yields 982N push at 0.5 MPa, while stepping up to 80mm provides 2513N. A self-valved SAIF63X175-10A beats a separate cylinder and remote valve when panel space is tight or wiring a distant station is costly across a large machine. It uses an AC220V terminal connection with PT threaded ports. Since the 5/2 valve only routes air and the cushion merely decelerates near stroke end, neither holds a load unpowered; for true position holding, select the SAIL lock or BSAI clamp-lock cylinder. When replacing, match the 63mm bore, 175mm stroke, 3/8 valve port, AC220V voltage, terminal entry, PT thread, and no magnet.
Quick checklist
The 63mm bore generates 1559N of push force and 1402N of pull force at 0.5 MPa. The built-in 4M310-10 valve provides an effective area of 30.0 mm2 (Cv 1.68) with a maximum frequency of 4 cycles per second.
It uses a 5/2 solenoid valve that holds position by pilot pressure, not a spring. The factory default retracts the rod when the AC220V coil is energised, but you can reposition the valve to extend-when-energised. No separate remote valve is needed.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.