The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF63X175S-10A is a genuine double-acting ISO 15552 cylinder with a Ø63mm bore, 175mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF63X175S-10A is a double-acting ISO 15552 profile cylinder featuring an integrated 4M310-10 5/2 solenoid valve. Delivering a Cv of 1.68 and a 30 mm2 effective orifice, it provides 1559 N of push force at 0.5 MPa. This configuration includes a carbon steel piston rod, PT tapered threading, and a built-in magnet for position sensing with CMSE reed and DMSE electronic switches. The unit operates on an AC220V terminal coil drawing 3.5 VA, actuating in 0.05 s with an IP65 rating.
Because the cylinder body rates to 1.0 MPa but the internal pilot valve limits supply to 0.15-0.8 MPa, the practical working range remains 0.15-0.8 MPa. The manifold links the valve to the cylinder using O10 x O6.5 PU tubing, keeping the 3/8 inch valve port distinct from the cylinder's own 3/8 inch port. Factory set to retract the rod when energized, the valve can be repositioned to extend on signal. This decentralized design eliminates remote plumbing and panel space.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF63X175S-10A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 175 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M16×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 63×175 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines with distributed stations, eliminating long air lines from a central manifold by self-switching via the AC220V coil.
The integrated 4M310 valve manifold saves valuable panel and footprint space, delivering 1559 N force without external plumbing.
Easily upgrade existing ISO 15552 interchangeable setups where adding external valves and tubing is impractical or too expensive.
Choose this 63 mm bore when a 50 mm bore (982 N push at 0.5 MPa) is insufficient or a 80 mm bore (2513 N push at 0.5 MPa) provides excessive force. The SAIF63X175S-10A excels in decentralized stations where running separate valve tubing is costly, as one AC220V terminal coil signal drives the actuator directly. For load-holding applications, note that the 5/2 valve routes air but does not lock the piston; a SAIL lock cylinder is required for true mechanical holding.
When replacing, verify the 175 mm stroke, 10 port code (3/8 inch), AC220V voltage, terminal entry, PT threads, and the -S magnet. The 4M310 valve supports 4 cycles per second maximum. At 175 mm stroke, side loads are minimal, but for any stroke over 300 mm, always use a guide to prevent rod binding.
Quick checklist
The 63 mm bore generates 1559 N push and 1402 N pull force at 0.5 MPa. The built-in 4M310-10 valve provides a 30 mm2 effective area (Cv 1.68) for high flow.
The 5/2 valve does not lock the load without live pressure. Factory set to retract when energized, the valve can be repositioned to extend on signal. No separate remote valve is needed.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.