The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF63X200S-08A is a genuine double-acting ISO 15552 cylinder with a Ø63mm bore, 200mm stroke and a built-in 4M310-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF63X200S-08A is a double-acting ISO 15552 profile cylinder that integrates a 4M310-08 5/2 solenoid valve directly onto its manifold. Driven by an AC220V terminal coil drawing 3.5 VA, it delivers a Cv of 1.40 and activates in 0.05 s. Because the cylinder body rates to 1.0 MPa but the integrated valve operates at 0.15-0.8 MPa, the practical working range for this assembled unit is 0.15-0.8 MPa. The carbon steel rod provides a push force of 1559 N at 0.5 MPa.
By controlling itself from a single electrical signal, it eliminates remote plumbing and saves panel space, making it ideal for decentralized machine stations. The manifold connects to the cylinder via PU tubing (O10 x O6.5), and the factory setting retracts the rod when the coil is energised, though you can reposition the valve to extend-when-energised. This -S variant includes a magnet for CMSE reed and DMSE electronic sensors.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF63X200S-08A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 200 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M16×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-08 (5/2) |
|---|---|
| Valve flow | 25.0 mm² (Cv 1.40) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 63×200 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M310-08. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Distributes control logic across large machinery without running long valve tubing back to a central manifold.
Provides 1559 N of push force at 0.5 MPa for securing workpieces during machining operations.
Simplifies machine upgrades where adding a separate valve island is physically or electrically impractical.
Choose this 63 mm bore when a 50 mm bore (982 N push at 0.5 MPa) is insufficient but an 80 mm bore (2513 N push) is excessive. The self-valved SAIF architecture beats a separate cylinder and remote valve in space-tight machines by consolidating air routing and wiring into one decentralized node. This specific SKU uses a PT1/4 cylinder port, a 1/4" valve port, an AC220V terminal connection, and a magnet for position sensing. For exact replacements, match the 63x200 dimensions, 4M310-08 valve, AC220V terminal coil, PT thread, and -S magnet.
At 200 mm stroke, side loads are moderate, but ensuring proper guide alignment will maximize seal life. Note that the 5/2 valve routes air and the cushions only decelerate near stroke end; neither holds the load without live pressure. For true mechanical load-holding, consider an AirTAC SAIL lock cylinder instead.
Quick checklist
At 0.5 MPa, this 63 mm bore cylinder generates 1559 N of push force and 1402 N of pull force. The integrated 4M310-08 5/2 valve provides an effective flow area of 25.0 mm2 (Cv 1.40) with a maximum frequency of 4 cycles per second.
No separate pilot is needed; the 4M310 valve is internally piloted. It holds its last position via pilot pressure, not a spring, so it is not a load-holding lock. The factory default retracts the rod when the AC220V coil is energised, but you can reposition the valve to extend-when-energised.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.