The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF63X200S-10B is a genuine double-acting ISO 15552 cylinder with a Ø63mm bore, 200mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF63X200S-10B is a double-acting ISO 15552 profile cylinder with a built-in 4M310-10 5/2 solenoid valve, delivering a 30.0 mm2 effective area (Cv 1.68). Driven by a DC24V terminal entry coil drawing 3.0 W, it switches itself from one electrical signal. The cylinder body rates to 1.0 MPa, but because the integrated valve operates at 0.15-0.8 MPa, the practical working range for this assembled unit is 0.15-0.8 MPa. It delivers 1559N push force at 0.5 MPa.
Factory set to retract the piston rod when the coil is energised, the valve can be repositioned to extend-when-energised if your machine logic requires it. This SKU includes a magnet (-S) for CMSE reed and DMSE electronic sensors, uses a carbon steel rod, and connects the manifold to the cylinder via O10xO6.5 PU tubing. The valve port is 3/8 (code 10) while the cylinder port is PT3/8. By eliminating remote valves, it cuts plumbing and panel space for decentralized stations.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF63X200S-10B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 200 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M16×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 63×200 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines with multiple stations, eliminating long air tubing runs by switching locally via the integrated 4M310 valve.
Saves valuable panel space by mounting the valve directly on the profile cylinder, perfect for tight machinery layouts.
Drops into existing ISO 15552 footprints, simplifying upgrades where adding a separate remote valve bank is impractical.
Choose this 63mm bore when a 50mm bore (982N push at 0.5 MPa) is too weak, but an 80mm bore (2513N push) is excessive. The self-valved SAIF architecture beats a separate cylinder and remote valve in space-tight machines or retrofits where running air tubing is costly. The DC24V terminal coil offers IP65 protection and a 0.05s response time, ideal for low-voltage control systems.
This unit does not hold its load without live pressure, as the 5/2 valve routes air rather than locking it; for load-holding applications consider SAIL. To replace this model, match the 63mm bore, 200mm stroke, 3/8 valve port, DC24V voltage, terminal entry, PT threads, and the -S magnet. The 200mm stroke is short enough that side-load guides are typically not required.
Quick checklist
At 0.5 MPa, this 63mm bore cylinder provides 1559N push and 1402N pull force. The built-in 4M310-10 valve has a 30.0 mm2 effective area (Cv 1.68) with a max frequency of 4 cycles per second.
No, it switches itself using the integrated 4M310 5/2 valve driven by a DC24V (3.0W) terminal coil. By default, the rod retracts when energised, but you can reposition the valve to extend-when-energised.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.