The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF63X500-10A is a genuine double-acting ISO 15552 cylinder with a Ø63mm bore, 500mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF63X500-10A is a double-acting ISO 15552 profile cylinder featuring an integrated 4M310-10 5/2 solenoid valve. This built-in valve provides an effective flow area of 30.0 mm2 (Cv 1.68) and operates at a maximum frequency of 4 cycles per second. Driven by an AC220V terminal entry coil drawing 3.5 VA, it activates in 0.05 seconds or less. The unit delivers 1559 N of push thrust and 1402 N of pull thrust at 0.5 MPa.
Because the 5/2 valve operates from 0.15 to 0.8 MPa, the practical working pressure for this assembled SAIF unit is 0.15-0.8 MPa, even though the bare cylinder rates to 1.0 MPa. The factory setting retracts the piston rod when the coil is energised, but you can reposition the valve to extend-when-energised. The manifold connects to the cylinder via O10 x O6.5 PU tubing, meaning the 3/8 inch valve port and the 3/8 inch cylinder port are distinct connections that eliminate remote plumbing.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF63X500-10A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 500 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M16×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 63×500 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates the need for long air tubing runs back to a central valve island, driving the 500 mm stroke directly from a single AC220V signal.
Provides 1559 N of push force at 0.5 MPa to actuate diverters or gates, with the built-in 4M310-10 valve ensuring fast 4 cycle/sec response.
Ideal for upgrading existing machinery where adding external pneumatic plumbing is costly, using the integrated manifold and O10 x O6.5 PU tubing.
Choose this 63 mm bore when a 50 mm bore (delivering 982 N push at 0.5 MPa) lacks the force for your load, but an 80 mm bore (2513 N push) is excessive. The 500 mm stroke falls within the 1500 mm standard maximum, but at this length you must account for side loads and use a guide to prevent rod bending. The self-valved design beats a separate cylinder and remote valve for decentralized stations by cutting panel space and tubing runs. Remember the 5/2 valve routes air and is not a lock; if you need load holding, select a SAIL lock cylinder instead. To replace this unit, match the 63 mm bore, 500 mm stroke, 10 (3/8 inch) valve port, AC220V terminal coil, PT thread type, and standard carbon steel rod.
Quick checklist
At 0.5 MPa, this 63 mm bore cylinder generates 1559 N of push force and 1402 N of pull force. The integrated 4M310-10 valve provides an effective area of 30.0 mm2 (Cv 1.68).
No, the built-in 5/2 solenoid valve switches the cylinder directly from the AC220V terminal coil signal. By default, the rod retracts when energised, but repositioning the valve changes it to extend-when-energised.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.