The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF80X1000-10B is a genuine double-acting ISO 15552 cylinder with a Ø80mm bore, 1000mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF80X1000-10B is a double-acting ISO 15552 profile cylinder featuring an integrated 4M310-10 5/2 solenoid valve. This specific SKU is configured with a DC24V terminal electrical entry consuming 3.0 W, a PT3/8 cylinder port, and a 3/8 valve port. The built-in valve offers an effective area of 30.0 mm2 (Cv 1.68) and switches at a maximum frequency of 4 cycles per second. Because the valve operates at 0.15-0.8 MPa, this defines the practical working pressure for the assembled unit, even though the bare cylinder rates to 1.0 MPa.
Delivering 2513 N of push force at 0.5 MPa, this self-switching actuator eliminates the need for a separate remote valve. The manifold connects to the cylinder via PU tubing (O10 x O6.5), saving panel space and simplifying decentralized installation across large machines. From the factory, the piston rod retracts when the coil is energised, but you can reposition the valve to extend-when-energised if your sequence requires it.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF80X1000-10B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø80 mm |
| Stroke | 1000 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 2513 N | 2268 N |
| 0.7 MPa | 3519 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 80×1000 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates long tubing runs in large factory layouts by switching the 2513 N thrust locally via the integrated 4M310 valve.
Ideal for 1000 mm stroke push-off or diverter applications where fitting a remote valve near the moving carriage is impractical.
Replaces standard cylinders in tight envelopes by removing the need for external valve manifolds, wiring directly to the DC24V terminal.
Choose this 80 mm bore when you need substantial thrust—stepping down to a 63 mm bore drops the 0.5 MPa push force to 1559 N, while stepping up to 100 mm yields 3927 N. The SAIF80X1000-10B is optimal for space-tight machines where running pneumatic tubing back to a centralized valve island is costly or complex. With a 1000 mm stroke, you must account for side-load risks; ensure proper guide rails are used to prevent rod binding. The 5/2 valve routes air to move the load, but it does not lock the position pneumatically—if you need fail-safe load holding, consider the SAIL lock series instead. To replace this unit, match the 80 mm bore, 1000 mm stroke, 3/8 valve port, DC24V voltage, terminal entry, PT threads, and standard carbon steel rod.
Quick checklist
At 0.5 MPa, this 80 mm bore cylinder generates 2513 N of push force and 2268 N of pull force. The integrated 4M310-10 valve provides a flow rate of 30.0 mm2 (Cv 1.68).
No, the built-in 4M310 5/2 valve switches the cylinder directly from the DC24V terminal signal. By default, the rod retracts when energised, but you can reposition the valve to extend-when-energised.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.