The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF80X175S-08A is a genuine double-acting ISO 15552 cylinder with a Ø80mm bore, 175mm stroke and a built-in 4M310-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF80X175S-08A is a double-acting ISO 15552 profile cylinder equipped with a built-in 4M310-08 5/2 solenoid valve. This integrated valve provides an effective flow area of 25.0 mm2 (Cv 1.40) and is wired for an AC220V coil with a standard terminal entry. Because the manifold block connects to the cylinder via PU tubing, the valve port (1/4") is distinct from the cylinder port (3/8"). The standard carbon steel rod includes a magnet for CMSE reed and DMSE electronic sensors.
Although the cylinder body rates to 1.0 MPa, the practical operating range for this assembled unit is 0.15-0.8 MPa due to the internal pilot valve limits. Delivering 2513 N of push force at 0.5 MPa, it switches itself from a single coil signal, eliminating remote plumbing. Factory set to retract when energised, the valve can be repositioned to extend on signal, making it ideal for decentralized stations.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF80X175S-08A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø80 mm |
| Stroke | 175 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-08 (5/2) |
|---|---|
| Valve flow | 25.0 mm² (Cv 1.40) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 2513 N | 2268 N |
| 0.7 MPa | 3519 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 80×175 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M310-08. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates the need to run long valve tubing from a central panel. The integrated 4M310 valve and AC220V terminal coil let this 80mm bore cylinder operate autonomously at distant machine zones.
Provides 2513 N of push force at 0.5 MPa directly at the work point. The built-in valve ensures rapid 4 cycle/sec switching without the lag of remote pneumatic lines.
Ideal for retrofits where adding new pneumatic plumbing is costly. You only need to run a single electrical signal to the terminal entry, simplifying machine updates.
Choose this 80mm bore when a 63mm cylinder (1402 N pull at 0.5 MPa) lacks thrust or a 100mm unit is too bulky. The self-valved SAIF architecture is superior to a separate cylinder and remote valve when you need to minimize panel space and tubing runs across a large machine. This 175mm stroke is under the 300mm side-load threshold, but always verify guide alignment. To replace this unit, match the 80mm bore, 175mm stroke, 4M310-08 valve, AC220V terminal coil, PT threads, and the -S magnet.
Remember that the 5/2 valve routes air but does not hold the load without live pressure; it is not a lock. For secure position holding during air loss, consider the AirTAC SAIL pneumatic lock or BSAI clamp-lock cylinders instead.
Quick checklist
The 80mm bore generates 2513 N push and 2268 N pull force at 0.5 MPa. The built-in 4M310-08 valve provides a 25.0 mm2 effective area (Cv 1.40) and operates at a maximum frequency of 4 cycles per second.
No, it switches itself using the integrated 4M310 5/2 valve driven by an AC220V terminal coil. By default, the rod retracts when the coil is energised, but you can reposition the valve to extend-when-energised. Note that the valve routes air but does not lock the load without pressure.