The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF80X300-08A is a genuine double-acting ISO 15552 cylinder with a Ø80mm bore, 300mm stroke and a built-in 4M310-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF80X300-08A is a double-acting ISO 15552 profile cylinder with a built-in 4M310-08 5/2 solenoid valve. Delivering a Cv of 1.40 and a 25.0 mm2 effective area, the integrated valve manifold switches the bore directly from a single AC220V terminal coil signal. The cylinder body features an extruded aluminum barrel with a carbon steel piston rod, generating 2513 N of push force at 0.5 MPa. Because the valve operates at 0.15-0.8 MPa, this sets the practical working pressure range for the assembled SAIF unit, even though the cylinder body itself rates to 1.0 MPa.
By self-switching at 4 cycles per second, this unit eliminates remote plumbing and saves panel space for decentralized installations. The manifold connects to the cylinder using O10 x O6.5 PU tubing, and the valve port (1/4) differs from the cylinder port (3/8). From the factory, the piston rod retracts when the coil is energised, but you can reposition the valve to extend-when-energised. The AC coil consumes 3.5 VA, features IP65 protection, and activates in 0.05 s or less.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF80X300-08A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø80 mm |
| Stroke | 300 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-08 (5/2) |
|---|---|
| Valve flow | 25.0 mm² (Cv 1.40) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 2513 N | 2268 N |
| 0.7 MPa | 3519 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 80×300 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M310-08. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates the need for a remote valve island, reducing tubing runs across large factory layouts.
The integrated manifold saves valuable panel and footprint space in compact assembly equipment.
Ideal for upgrading older machines where running new pneumatic valve tubing is costly or difficult.
Choose this 80 mm bore when a 63 mm bore (providing 1559 N push at 0.5 MPa) is insufficient, but a 100 mm bore (3927 N) is oversized. The 300 mm stroke is well within the 1500 mm standard maximum, but at this length you should account for potential side-load and use a guide to prevent rod binding. The 4M310-08 valve provides ample flow for the bore, while the AC220V terminal connection offers straightforward wiring. Because the 5/2 valve holds position via internal pilot pressure and the air cushion only decelerates near stroke end, this unit does not lock or hold loads without live pressure; for true load-holding, consider the SAIL lock cylinder. To replace this unit, match the 80 mm bore, 300 mm stroke, 1/4 valve port, AC220V voltage, terminal entry, PT thread, and no magnet (-S omitted).
Quick checklist
The 80 mm bore generates 2513 N of push force and 2268 N of pull force at 0.5 MPa. The built-in 4M310-08 valve provides a 25.0 mm2 effective area (Cv 1.40) to drive the cylinder.
The integrated 5/2 valve routes air to switch the cylinder from a single AC220V coil signal, meaning no separate valve is needed. By default, the rod retracts when energised, but it can be reconfigured to extend. The valve and air cushion do not lock the load; live pressure is required to hold position.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.