The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF80X600S-08A is a genuine double-acting ISO 15552 cylinder with a Ø80mm bore, 600mm stroke and a built-in 4M310-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF80X600S-08A is a double-acting ISO 15552 profile cylinder featuring an integrated 4M310-08 5/2 solenoid valve. Driven by an AC220V terminal coil drawing 3.5 VA, it delivers a robust 2513N push force at 0.5 MPa. The integrated valve boasts a 25.0 mm2 orifice (Cv 1.40) and switches up to 4 cycles per second. Because the manifold block mounts directly to the cylinder using O10 x O6.5 PU tubing, you eliminate remote plumbing and save panel space.
While the bare cylinder body rates to 1.0 MPa, the practical operating range for this valved assembly is 0.15-0.8 MPa. Factory-set to retract the rod when the coil is energised, the valve can be repositioned to extend-when-energised if your sequence demands it. This 80mm bore unit includes a magnet for CMSE reed and DMSE electronic sensors, operating at speeds of 30-800 mm/s.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF80X600S-08A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø80 mm |
| Stroke | 600 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-08 (5/2) |
|---|---|
| Valve flow | 25.0 mm² (Cv 1.40) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 2513 N | 2268 N |
| 0.7 MPa | 3519 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 80×600 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M310-08. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large multi-station presses where local actuation removes the need for long, lagging air lines from a central control bank.
Provides robust 2513N push force for diverting heavy pallets, with the built-in valve minimizing wiring complexity across long conveyor frames.
Fits tight OEM envelopes where a separate valve island would require an oversized electrical cabinet and additional pneumatic plumbing.
Choose this 80mm bore when a 63mm unit lacks thrust (the 63mm delivers 1559N push at 0.5 MPa) or a 100mm unit is oversized (pushing 3927N). A 600mm stroke demands careful attention to side loads; always use a guide rail to prevent rod bending and premature seal wear. The self-contained AC220V terminal design excels in decentralized stations where running air tubing from a central manifold is costly or complex.
If your process drops power and requires the load to stay put mechanically, note that this 5/2 valve routes air but does not lock the piston; consider an AirTAC SAIL lock cylinder instead. To replace this unit, match the 80mm bore, 600mm stroke, PT1/4 cylinder port, 4M310-08 valve with PT thread, AC220V voltage, terminal entry, and the -S magnet.
Quick checklist
At 0.5 MPa, this 80mm bore cylinder generates 2513N of push force and 2268N of pull force. The integrated 4M310-08 5/2 valve provides an effective flow area of 25.0 mm2 (Cv 1.40).
No separate remote valve is needed. The internally piloted 4M310 valve switches the cylinder directly from the AC220V terminal coil signal. Factory-set to retract when energised, you can reposition the valve to extend-when-energised.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.