The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF80X75-08A is a genuine double-acting ISO 15552 cylinder with a Ø80mm bore, 75mm stroke and a built-in 4M310-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF80X75-08A is a double-acting ISO 15552 profile cylinder featuring an integrated 4M310-08 5/2 solenoid valve. This built-in valve provides an effective flow area of 25.0 mm2 (Cv 1.40) and mounts directly via a manifold block using O10 x O6.5 PU tubing. Driven by an AC220V terminal connection coil drawing 3.5 VA, it activates in 0.05 s or less with an IP65 rating. While the bare cylinder rates to 1.0 MPa, the integrated valve limits the practical operating pressure to 0.15-0.8 MPa.
Delivering 2513N of push force at 0.5 MPa and up to 4523N at 0.9 MPa, this unit eliminates the need for a separate remote valve. The factory setting retracts the piston rod when the coil is energised, but you can reconfigure it to extend-when-energised by simply repositioning the valve. It is a self-switching solution ideal for decentralized stations across large machines.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF80X75-08A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø80 mm |
| Stroke | 75 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-08 (5/2) |
|---|---|
| Valve flow | 25.0 mm² (Cv 1.40) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 2513 N | 2268 N |
| 0.7 MPa | 3519 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 80×75 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M310-08. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large-scale automated machinery where running individual valve tubing back to a central panel is costly and complex.
Provides robust 4523N push force at 0.9 MPa for holding heavy workpieces securely during machining or welding operations.
The integrated valve manifold saves valuable real estate on tight machine frames, delivering self-switched actuation without external plumbing.
Choose this 80mm bore model when your application requires substantial thrust that a 63mm bore (1559N push at 0.5 MPa) cannot provide, but a 100mm unit is excessive. The 75mm stroke is well within the 1500mm maximum standard, making it highly responsive for shorter cycles. The integrated 4M310-08 valve handles up to 4 cycles per second, matching the 30-800 mm/s speed range of the cylinder.
This SAIF assembly is selected over a plain SAI cylinder with remote plumbing when you need to minimize panel space and tubing runs. The AC220V terminal coil offers straightforward wiring, and the valve port is 1/4" (code 08) while the cylinder port is 3/8". Note that the 5/2 valve routes air but does not hold the load without live pressure; for true mechanical locking, consider the SAIL series. When ordering a replacement, verify the 80mm bore, 75mm stroke, 1/4" valve port, AC220V voltage, terminal entry, PT threads, and the absence of a magnet (-S).
Quick checklist
The 80mm bore generates 2513N push force at 0.5 MPa and 4523N at 0.9 MPa. The built-in 4M310-08 valve provides an effective flow area of 25.0 mm2 (Cv 1.40).
No separate remote valve is needed; one AC220V coil signal drives the cylinder. The factory setting retracts the rod when energised, but you can reposition the valve to extend-when-energised.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.