The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF100X160-08A is a genuine double-acting profile-type cylinder with a Ø100mm bore, 160mm stroke and a built-in 4M310-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF100X160-08A is a double-acting profile cylinder with a built-in AirTAC 4M310-08 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel makes it shorter than a standard ISO 15552 unit of the same bore. It uses a Ø25 mm piston rod with an M20x1.5 thread, a 1/2" cylinder port, and 29 mm adjustable cushions.
Operating within the valve's 0.15-0.8 MPa window, it delivers 3927 N push force at 0.5 MPa. The integrated valve provides 25 mm2 flow (Cv 1.4) and handles up to 4 cycles per second. For sizing, the safe working load is roughly 2356 N, and it can vertically lift about 200 kg with a 2:1 margin. This terminal-entry AC220V model has no magnet, so it cannot accept a magnetic switch.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF100X160-08A |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø100 mm |
| Stroke | 160 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/2" |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-08 (5/2) |
|---|---|
| Valve flow | 25.0 mm² (Cv 1.40) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa | 5498 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 100×160 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M310-08. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Decentralized clamping on a large machining center. The built-in valve switches the clamp directly at the cap, saving tubing runs back to a central manifold.
Actuating a heavy diverter on a packaging line. The 4M310-08 valve provides Cv 1.4 flow for rapid shifting without a separate remote valve bank.
Lifting pallets at an assembly cell. The 100 mm bore provides the push force needed, with one coil signal simplifying the electrical install.
Size against the 63 mm and 80 mm neighbors: this 100 mm bore gives 3927 N push at 0.5 MPa versus 2513 N for the 80 mm. Confirm the AC220V terminal entry matches your control voltage. The rod retracts when the coil is energized, but you can reposition the valve to extend on signal. Always size force within the 0.15-0.8 MPa valve range, not the 1.0 MPa cylinder body rating. The valve routes air but does not lock the load; add an external rod lock or pilot-operated check valve for holding. For this 160 mm stroke side-load is minimal, but any stroke over 300 mm requires a guide to prevent rod binding.
Quick checklist
It pushes 3927 N and pulls 3681 N at 0.5 MPa, reaching 6282 N at 0.8 MPa. The built-in valve is a 4M310-08 (1/4" port, Cv 1.4, 4 cycles/sec max) on a 100 mm bore with a 1/2" cylinder port. The coil is AC220V terminal entry. Size force within the valve's 0.15-0.8 MPa operating window, not the 1.0 MPa cylinder body rating.
Yes. The integrated 5/2 solenoid means one coil signal switches the cylinder directly, saving manifold slots and tubing. The rod retracts by default when energized, but you can reposition the valve to extend on signal. Note the valve routes air and is not a load lock.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.