The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF100X175S-10A is a genuine double-acting profile-type cylinder with a Ø100mm bore, 175mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF100X175S-10A is a double-acting profile cylinder with a built-in AirTAC 4M310 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel is shorter than an ISO 15552 unit of the same bore. The 100mm bore uses a 1/2" port, a Ø25mm rod, and M20x1.5 rod thread. The 175mm stroke is above the 75mm minimum, and the piston magnet supports CMSG/DMSG/EMSG switches.
The integrated 4M310-10 valve features a 3/8" port, Cv 1.68 flow, and a 4 cycle/sec limit. It runs on AC220V via terminal entry. Size force within the 0.15-0.8 MPa valve window, not the 1.0 MPa cylinder body rating. At 0.5 MPa it pushes 3927 N and pulls 3681 N. A computed buyer insight: safe working load is roughly 2356 N (60% of the 0.5 MPa push), allowing a 200 kg vertical lift with a 2:1 margin.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF100X175S-10A |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø100 mm |
| Stroke | 175 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/2" |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa | 5498 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 100×175 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Decentralized clamping on a large press line. The built-in 4M310 valve delivers high flow directly to the 100mm bore, actuating heavy clamps without a remote manifold.
One coil signal per actuator simplifies wiring across a sprawling welding station. The AC220V terminal entry integrates cleanly into standard plant control panels.
Robust 3927 N push force at 0.5 MPa halts heavy pallets. The profile barrel saves space, and the integrated valve cuts down tubing clutter on the conveyor frame.
Size by checking both neighboring bores and the 0.5 MPa force: the 80mm bore pushes 2513 N, while this 100mm bore pushes 3927 N. Confirm your coil is AC220V with terminal entry, and that your PU tube matches the required Ø10xØ6.5. The default action retracts the rod when energized, but you can reposition the valve to extend on signal. Always size within the 0.15-0.8 MPa valve operating range. The valve only routes air, so for load holding add an external rod lock or pilot-operated check valve. Since the 175mm stroke is under 300mm, extreme side-load guides are less critical, but standard alignment is still advised.
Quick checklist
It pushes 3927 N and pulls 3681 N at 0.5 MPa. The built-in valve is a 4M310-10 (3/8" port, Cv 1.68, max 4 cycles/sec). The coil is AC220V with terminal entry. Although the cylinder body rates to 1.0 MPa, you must size force within the built-in valve's 0.15-0.8 MPa operating window.
Yes. The default action retracts the rod when energized, but you can reposition the valve to extend the rod on signal. Because the valve only routes air, it is not a load lock; add an external rod lock or pilot-operated check valve if you need to hold a load securely.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.