The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF100X300-10B is a genuine double-acting profile-type cylinder with a Ø100mm bore, 300mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF100X300-10B is a double-acting profile cylinder with a built-in AirTAC 4M310 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel is shorter than an ISO 15552 cylinder of the same bore. This 100mm bore uses a 1/2" cylinder port, a Ø25mm rod with M20x1.5 thread, and 29mm adjustable cushions.
Driven by a 4M310-10 valve (3/8" port, Cv 1.68, 4 cycles/s max), it operates on DC24V terminal entry with PT threads. The cylinder body rates to 1.0 MPa, but the assembled unit functions within the valve's 0.15-0.8 MPa window. At 0.5 MPa it delivers 3927N push force. A computed buyer insight: safe working load is roughly 2356N (60% of the 0.5MPa push), yielding a 200kg vertical lift capacity with a 2:1 margin.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF100X300-10B |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø100 mm |
| Stroke | 300 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/2" |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa | 5498 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 100×300 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Decentralized clamping on a large press line. The integrated 4M310 valve handles the high 3927N push force locally without routing long tubing back to a central manifold.
A 300mm stroke diverter on a heavy material conveyor. One DC24V signal actuates the 100mm bore directly at the station, saving manifold space and simplifying installation.
Operating a heavy routing gate in an automated warehouse. The self-contained pneumatic actuator provides rapid 4 cycles/s shifting with a robust 1.68 Cv flow rate.
When sizing, compare neighboring bores: the 80mm bore offers 2513N push while the 100mm bore provides 3927N push at 0.5 MPa. Always size force within the 0.15-0.8 MPa valve operating range, never the 1.0 MPa cylinder body rating. Confirm the DC24V terminal entry and PT thread meet your electrical specs. By default the rod retracts when energized; repositioning the valve switches it to extend-when-energized. Because this is a 300mm stroke, add external guides to prevent rod bending and side-load wear. The built-in valve routes air but does not lock the piston; for load holding on air loss, add an external rod lock or pilot-operated check valve. This SKU lacks a magnet (-S) and cannot accept magnetic switches.
Quick checklist
It generates 3927N push and 3681N pull at 0.5 MPa. The built-in valve is a 4M310-10 (3/8" port, Cv 1.68, max 4 cycles/s) running on a DC24V terminal coil. Although the cylinder body rates to 1.0 MPa, the assembled unit must operate within the valve's 0.15-0.8 MPa window. The cylinder port is 1/2".
Yes. The default action retracts the rod when the coil is energized. You can reconfigure it to extend-when-energized simply by repositioning the built-in valve on the cap. This allows flexible machine sequencing without altering your electrical controls.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.