The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF100X600-08B is a genuine double-acting profile-type cylinder with a Ø100mm bore, 600mm stroke and a built-in 4M310-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF100X600-08B is a double-acting profile cylinder with a built-in AirTAC 4M310 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel makes it shorter than an ISO 15552 cylinder of the same bore. It uses a Ø25 mm rod, M20x1.5 rod thread, 1/2 inch cylinder port, and 29 mm adjustable cushions.
Driven by a DC24V terminal-entry coil, the integrated 4M310-08 valve has a 1/4 inch port, Cv 1.4 flow, and cycles up to 4 times per second. The cylinder body rates to 1.0 MPa, but the assembled unit operates strictly within the 0.15-0.8 MPa valve window. At 0.5 MPa it pushes 3927 N and pulls 3681 N. For sizing, the safe working load is roughly 2356 N, allowing a vertical lift of about 200 kg with a 2:1 margin. PU tube size is Ø10xØ6.5.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF100X600-08B |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø100 mm |
| Stroke | 600 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/2" |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-08 (5/2) |
|---|---|
| Valve flow | 25.0 mm² (Cv 1.40) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa | 5498 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 100×600 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M310-08. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Uses the built-in valve to switch a heavy divert gate directly at the conveyor, eliminating long tubing runs back to a central manifold.
Acts as a standalone pallet stop in a large facility, needing only one DC24V signal to drive the 600 mm stroke without extra plumbing.
Provides localized 3927 N clamping force on a remote press station, saving manifold slots and simplifying machine installation.
Size force between 0.15 and 0.8 MPa. At 0.5 MPa this 100 mm bore delivers 3927 N push and 3681 N pull; the neighbouring 80 mm bore gives 2513 N push. If you need more power, the 100 mm bore reaches 6282 N at 0.8 MPa. Confirm the DC24V terminal entry and PT thread suit your control panel. The rod retracts when the coil is energised, but you can reposition the valve to extend on signal. The valve routes air and is not a load lock; add an external rod lock or pilot-operated check valve to hold a load. The 600 mm stroke demands an external guide to prevent rod bending and side-load wear. This SKU lacks a magnet and cannot take a sensor.
Quick checklist
It generates 3927 N push and 3681 N pull at 0.5 MPa, reaching 6282 N at 0.8 MPa. The built-in 4M310-08 valve has a 1/4 inch port, Cv 1.4, and runs on a DC24V terminal-entry coil. Although the cylinder body rates to 1.0 MPa, the assembled unit must operate within the 0.15-0.8 MPa valve window.
The valve routes air and is not a load lock, so the piston drifts on air loss; add an external rod lock or pilot-operated check valve to hold a load. By default the rod retracts when the coil is energised, but you can reposition the valve to extend on signal. This SKU has no magnet and cannot accept a sensor.