The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF100X75S-08A is a genuine double-acting profile-type cylinder with a Ø100mm bore, 75mm stroke and a built-in 4M310-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF100X75S-08A is a double-acting profile cylinder with a built-in AirTAC 4M310 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel is shorter than an ISO 15552 cylinder of the same bore. The 1/2" cylinder port and M20x1.5 rod thread handle high flow.
Operating in the 0.15-0.8 MPa valve window, it delivers 3927 N push at 0.5 MPa. The 4M310-08 valve has a 1/4" port, Cv 1.4, and runs up to 4 cycles/sec. The AC220V terminal coil is IP65 rated. With a 75 mm stroke, the 29 mm cushions decelerate the load. Safe working load is roughly 2356 N, allowing a 200 kg vertical lift with a 2:1 margin.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF100X75S-08A |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø100 mm |
| Stroke | 75 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/2" |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-08 (5/2) |
|---|---|
| Valve flow | 25.0 mm² (Cv 1.40) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa | 5498 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 100×75 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M310-08. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Decentralized clamping in a large press line. The built-in valve provides immediate local actuation without routing long control lines back to a central manifold.
Diverting heavy pallets on a conveyor. One coil signal per actuator simplifies control logic and reduces tubing complexity across the wide machine frame.
Lifting loaded pallets at a packing station. The 100 mm bore provides the necessary force, while the integrated valve minimizes installation time.
Size by comparing the 100 mm bore (3927 N push @0.5 MPa) against the 80 mm neighbor (2513 N). Confirm the AC220V terminal entry and PT threads. Default action retracts the rod when energized; reposition the valve to extend on signal. Size force strictly within the 0.15-0.8 MPa valve range, never the 1.0 MPa cylinder body rating. The valve routes air but does not lock; add an external rod lock or pilot-operated check valve to hold loads. The S suffix provides a piston magnet for sensors. For strokes over 300 mm, guide the load to prevent side-load wear.
Quick checklist
It pushes 3927 N and pulls 3681 N at 0.5 MPa. The built-in valve is a 4M310-08 (1/4" port, Cv 1.4) running on AC220V. The cylinder body rates to 1.0 MPa, but you must size force within the valve's 0.15-0.8 MPa operating window.
By default the rod retracts when the coil is energized; you can reposition the valve to extend on signal. The 5/2 valve routes air but does not lock the piston. For load holding on air loss, install an external rod lock or pilot-operated check valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.