The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF100X75S-10A is a genuine double-acting profile-type cylinder with a Ø100mm bore, 75mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF100X75S-10A is a double-acting profile cylinder with a built-in AirTAC 4M310-10 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The hard-anodized aluminum barrel is shorter than an ISO 15552 unit of the same bore. This 100mm bore version pushes 3927N and pulls 3681N at 0.5MPa, operating within the valve's 0.15-0.8MPa range. The cylinder port is 1/2".
The integrated valve features a 3/8" port, 30mm2 flow (Cv 1.68), and cycles up to 4 times per second. It uses an AC220V terminal entry coil rated IP65. The -S suffix provides a piston magnet for CMSG/DMSG/EMSG sensors. For sizing, the safe working load is roughly 2356N (about 60% of the 0.5MPa push force), supporting a vertical lift of approximately 200kg with a 2:1 margin.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF100X75S-10A |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø100 mm |
| Stroke | 75 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/2" |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa | 5498 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 100×75 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Clamps heavy parts directly at the press station using one AC220V signal, bypassing a central manifold for faster cycle response.
Actuates heavy diverting gates along a conveyor line independently, cutting tubing runs back to a main control panel.
Lifts pallets vertically in localized zones, leveraging the 200kg vertical lift capacity without complex remote plumbing.
Size this 100mm bore against the 80mm option (2513N push at 0.5MPa) or larger custom actuators, using the 3927N push figure at 0.5MPa as your baseline. Confirm the AC220V terminal entry and 3/8" valve port match your supply. The default action retracts the rod when energized, but you can reposition the valve to extend on signal. Always size force within the 0.15-0.8MPa valve window, not the 1.0MPa cylinder body rating. The integrated valve routes air and is not a load lock; add an external rod lock or pilot-operated check valve to hold loads safely. For strokes of 300mm or longer, use side-load guides.
Quick checklist
It delivers 3927N push and 3681N pull at 0.5MPa, reaching 6282N push at 0.8MPa. The built-in valve is a 4M310-10 (3/8" port, Cv 1.68) driven by an AC220V terminal coil. You must size the force within the valve's 0.15-0.8MPa operating window, even though the cylinder body rates to 1.0MPa.
Yes, the default action retracts the rod on signal, but you can reposition the valve to extend when energized. The valve only routes air; it is not a load lock. The piston will drift on air loss, so install an external rod lock or pilot-operated check valve for load holding.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.