The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X150-06A is a genuine double-acting profile-type cylinder with a Ø32mm bore, 150mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF32X150-06A is a double-acting profile cylinder with a built-in AirTAC 4M210 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel makes it shorter than an ISO 15552 cylinder of the same bore. It features a 32mm bore, 150mm stroke, 1/8" cylinder port, and an M10x1.25 rod thread.
Operating within the 0.15-0.8 MPa valve window, it delivers 402N push force at 0.5 MPa. The integrated 4M210-06 valve has a 1/8" port, 14 mm2 flow (Cv 0.78), and handles 5 cycles/sec. The AC220V terminal entry coil is IP65 rated. For sizing, the safe working load is roughly 241N, and vertical lift capacity is about 20kg with a 2:1 margin. This SKU lacks a magnet, so it cannot accept a magnetic switch.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X150-06A |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 150 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/8" |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 32×150 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Ideal for a clamping station on a large machine, using the built-in valve to actuate locally without running long tubing back to a central manifold.
Powers a small diverter gate on a conveyor line, where the integrated 4M210 valve provides fast 5 cycle/sec actuation right at the point of use.
Fits into tight multi-station sorting modules, saving manifold space by switching each cylinder independently with a single AC220V signal.
Size force between the 0.15-0.8 MPa valve limits, despite the 1.0 MPa cylinder body rating. At 0.5 MPa this 32mm bore provides 402N push and 345N pull; if you need more force, step up to the 40mm bore (628N push). The 150mm stroke is well within the 1000mm maximum and above the 50mm minimum. Confirm the AC220V terminal coil voltage for your control system. By default the rod retracts when energised; repositioning the valve changes it to extend-when-energised. The valve routes air and is not a load lock—add an external rod lock or pilot-operated check valve to hold a load. For this 150mm stroke, standard guidance handles side loads adequately.
Quick checklist
It generates 402N push and 345N pull at 0.5 MPa. The built-in valve is a 4M210-06 (1/8" port, Cv 0.78, 5 cycles/sec) driven by an AC220V terminal coil. Although the cylinder body rates to 1.0 MPa, the assembled unit must operate within the 0.15-0.8 MPa valve window.
The default action retracts the rod when energised. You can reconfigure it to extend-when-energised simply by repositioning the valve. Because this is a 5/2 valve that routes air, it is not a load lock; use an external rod lock or pilot-operated check valve if you need to hold a load.