The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X150-08B is a genuine double-acting profile-type cylinder with a Ø32mm bore, 150mm stroke and a built-in 4M210-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF32X150-08B is a double-acting profile cylinder with a built-in AirTAC 4M210 5/2 solenoid valve on the cap. One DC24V coil signal drives the rod, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel makes it shorter than an ISO 15552 unit of the same bore. It has a 1/8" cylinder port, M10x1.25 rod thread, and 21mm cushions.
Operating strictly within the valve's 0.15-0.8 MPa window, this 32mm bore delivers 402N push and 345N pull at 0.5 MPa. The integrated 4M210-08 valve has a 1/4" port, Cv 0.89 flow, and handles 5 cycles/sec. For sizing, the safe working load is roughly 241N, and it can vertically lift about 20kg with a 2:1 margin. This terminal-entry, PT-threaded SKU lacks a magnet, so it cannot accept a sensor.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X150-08B |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 150 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/8" |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-08 (5/2) |
|---|---|
| Valve flow | 16.0 mm² (Cv 0.89) |
| Max frequency | 5 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 32×150 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M210-08. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Ideal for a clamping station where running a single DC24V signal to the cap valve is faster than plumbing a remote manifold.
A short-stroke diverter gate that benefits from the 5 cycles/sec speed of the 4M210 valve and the compact profile barrel.
Perfect for standalone gantry axes where saving manifold slots and minimizing tubing between the controller and cylinder is critical.
Size by force: this 32mm bore gives 402N push at 0.5 MPa, whereas the 40mm bore gives 628N. If your load is lighter, confirm if a smaller actuator works. Always size within the 0.15-0.8 MPa valve range, not the 1.0 MPa cylinder body rating. Verify you need DC24V terminal entry before ordering. The rod retracts when the coil energises; reposition the valve to invert this. Since this SKU lacks the -S suffix, it cannot take a magnetic switch. The valve routes air but does not lock the piston; add an external rod lock or pilot-operated check valve to hold a load. For this 150mm stroke, guide any side loads.
Quick checklist
It pushes 402N and pulls 345N at 0.5 MPa. The built-in valve is a 4M210-08 (1/4" port, Cv 0.89) running on DC24V. Although the cylinder body rates to 1.0 MPa, you must size force within the valve's 0.15-0.8 MPa operating window.
By default the rod retracts when the coil is energised, but you can reposition the valve to extend on signal. The 5/2 valve only routes air; it is not a load lock. If you need to hold a load against air loss, install an external rod lock or pilot-operated check valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.