AirTAC SAUF Series · Profile Cylinder with Valve

Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X50-06B

The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X50-06B is a genuine double-acting profile-type cylinder with a Ø32mm bore, 50mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.

  • BoreØ32 mm
  • Stroke50 mm
  • Built-in valve4M210-06
  • Valve port1/8"
  • CoilDC24V
  • EntryTerminal
$87.43 $94.93Save 7% Usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X50-06B

The AirTAC SAUF32X50-06B is a double-acting profile cylinder with a built-in 4M210 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel is shorter than an ISO 15552 cylinder of the same bore. This 32mm bore uses a 1/8" cylinder port and a 12mm rod with an M10x1.25 thread.

Operating within the 0.15-0.8 MPa valve window, it delivers 402N push at 0.5 MPa. The integrated 4M210-06 valve has a 1/8" port, 14 mm2 flow (Cv 0.78), and cycles up to 5 times per second. The DC24V coil uses 3.0W with IP65 protection and terminal entry. For sizing, the safe working load is roughly 241N (60% of the 0.5MPa push force), allowing a vertical lift of about 20kg with a 2:1 margin.

Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X50-06B Technical Specifications

ModelAirtac SAUF Series Valve-Mounted Air Cylinder SAUF32X50-06B
SeriesSAUF profile cylinder with valve
Bore sizeØ32 mm
Stroke50 mm
Acting typeDouble acting, self-valved
Cylinder port1/8"
Rod threadM10×1.25
PU tubeØ8 × Ø5
Built-in valve4M210-06 (5/2)
Valve flow14.0 mm² (Cv 0.78)
Max frequency5 cycle/sec
Coil voltageDC24V · DC 3.0 W
Electrical entryTerminal · IP65 · B class
Response time0.05 s and below
Operating pressure0.15 – 0.8 MPa (valve limit)
Speed range30 – 800 mm/s

The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.

Theoretical Output Force (Ø32mm)

PressurePush forcePull force
0.5 MPa402 N346 N
0.7 MPa563 N

Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.

Model Code: Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X50-06B

SAUFProfile cylinder with built-in 4M valve.
32×50Bore × stroke in mm.
-06Valve port 1/8" → 4M210-06.
BCoil voltage DC24V.
I / (blank)Terminal electrical entry.

SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.

Where the Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X50-06B Is Used

view_module

Modular Assembly Cells

Distributes individual actuator control across large machines without routing long tube runs back to a central manifold.

widgets

Small Part Ejection

Handles compact ejection tasks at up to 5 cycles per second using the integrated 4M210 valve for rapid local switching.

conveyor_belt

Diverter Gates

Powers lightweight routing flaps directly at the conveyor zone, minimizing response delay with the built-in 5/2 valve.

Is the Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X50-06B the Right Choice?

Size this 32mm bore against the 40mm option (628N push at 0.5 MPa) to ensure adequate force. This DC24V terminal entry model operates at 0.15-0.8 MPa; do not exceed 0.8 MPa despite the 1.0 MPa cylinder body rating. By default the rod retracts when energised, but repositioning the valve changes it to extend-when-energised. This SKU lacks a magnet and cannot accept a magnetic switch. The valve routes air and does not hold loads; add an external rod lock or pilot-operated check valve for drop protection. For strokes over 300mm, use side-load guides.

Quick checklist

  • ✓ Force at 0.15–0.8 MPa
  • ✓ Coil voltage matches panel
  • ✓ Terminal vs grommet entry
  • ✓ Retract- or extend-when-energised
  • ✓ Load-holding → external rod lock
Ask an Engineer

Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X50-06B FAQ

It pushes 402N and pulls 345N at 0.5 MPa. The built-in valve is a 4M210-06 (1/8" port, Cv 0.78, 5 cycles/sec max) driven by a DC24V coil. The assembled unit operates strictly within a 0.15-0.8 MPa pressure window.

No. The integrated 5/2 valve routes air but does not lock the piston. If air is lost, the load will drift. You must add an external rod lock or pilot-operated check valve for secure load holding.

Related AirTAC Cylinders & Valves

Request a Quote for Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X50-06B

Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for SAUF32X50-06B and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.