The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X75-06B is a genuine double-acting profile-type cylinder with a Ø32mm bore, 75mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF32X75-06B is a double-acting profile cylinder with a built-in AirTAC 4M210-06 5/2 solenoid valve on the cap. One coil signal switches the cylinder directly, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel makes it shorter than an ISO 15552 unit of the same bore.
It pushes 402 N and pulls 345 N at 0.5 MPa. The 1/8" ported valve flows 14 mm2 (Cv 0.78) at up to 5 cycles/s. Size force within the valve's 0.15-0.8 MPa window. For practical sizing, the safe working load is roughly 241 N, and it can vertically lift about 20 kg with a 2:1 margin. This DC24V terminal-entry coil is IP65 rated. Note this SKU lacks a magnet and cannot take a sensor.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X75-06B |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 75 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/8" |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 32×75 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Drives individual clamps across a large fixture using one DC24V signal per actuator, bypassing a central manifold.
Powers small routing gates on a conveyor directly at the point of action, cutting tubing runs back to a control cabinet.
Ejects small parts from a machine cell where space is tight, leveraging the short profile barrel and integrated switching.
Size by comparing neighbours: the 32 mm bore gives 402 N push at 0.5 MPa, while the next size up yields 628 N. Confirm the DC24V terminal entry and PT threads suit your control panel. The rod retracts when energised by default, but you can reposition the valve to extend on signal. Because the 4M210 valve limits operation to 0.15-0.8 MPa, never size the assembled unit to the 1.0 MPa cylinder body rating. The valve only routes air; it is not a lock, so add an external rod lock or pilot-operated check valve to hold a load. For this 75 mm stroke side-load is minimal, but guide any stroke over 300 mm.
Quick checklist
It delivers 402 N push and 345 N pull at 0.5 MPa. The built-in valve is a 4M210-06 (1/8" port, Cv 0.78, 5/2 solenoid) running on DC24V. Although the cylinder body rates to 1.0 MPa, the assembled unit operates strictly within the valve's 0.15-0.8 MPa window.
The valve routes air and is not a load lock, so the piston drifts on air loss—add an external rod lock for holding. By default the rod retracts when the coil is energised, but you can reposition the valve to make it extend on signal.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.