The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF40X1000S-06B is a genuine double-acting profile-type cylinder with a Ø40mm bore, 1000mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF40X1000S-06B is a double-acting profile cylinder with a built-in AirTAC 4M210 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel is shorter than an ISO 15552 unit of the same bore. The S suffix indicates a piston magnet for CMSG/DMSG/EMSG switches.
Operating within the valve's 0.15-0.8 MPa window, this 40mm bore generates 628N push and 528N pull at 0.5 MPa. The 4M210-06 valve has a 1/8" port, 14mm2 flow (Cv 0.78), and cycles up to 5 times per second. Computed buyer insight: safe working load is roughly 377N (60% of the 0.5MPa push force), supporting a vertical lift of about 32kg with a 2:1 margin. The cylinder port is 1/4".
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF40X1000S-06B |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø40 mm |
| Stroke | 1000 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/4" |
| Rod thread | M12×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 628 N | 528 N |
| 0.7 MPa | 880 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 40×1000 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Mounts directly at the divert station. One DC24V signal actuates the gate without routing air lines back to a central manifold.
The 1000mm stroke handles deep pallet indexing. Ensure external linear guides support the rod over this extended travel.
Self-switching actuation simplifies machine wiring. The 4M210-06 valve cycles up to 5 times per second for fast carton pushing.
Size force within the 0.15-0.8 MPa valve range, not the 1.0 MPa cylinder body rating. This 40mm bore pushes 628N at 0.5 MPa; dropping to 32mm yields 402N, while stepping up to 50mm provides 982N. Confirm the DC24V terminal entry and PT threads. Default action retracts the rod when energised; reposition the valve to extend on energisation. The built-in valve routes air and is not a load lock—add an external rod lock or pilot-operated check valve to hold loads. For the 1000mm stroke, use external guides to prevent rod bending and side loads.
Quick checklist
It pushes 628N and pulls 528N at 0.5 MPa. The built-in valve is a 4M210-06 (1/8" port, Cv 0.78, 5 cycles/sec max) with a DC24V coil. Size forces within the 0.15-0.8 MPa valve operating window, as the assembled unit cannot use the cylinder body's 1.0 MPa maximum.
No. The built-in 5/2 valve routes air but does not lock the piston. If air is lost, the rod drifts. Install an external rod lock or pilot-operated check valve for load holding. The default action retracts the rod when energised, but you can reposition the valve to extend on energisation.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.