The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF50X450-08B is a genuine double-acting profile-type cylinder with a Ø50mm bore, 450mm stroke and a built-in 4M210-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF50X450-08B is a double-acting profile cylinder with a built-in AirTAC 4M210-08 5/2 solenoid valve on the cap. One DC24V coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel makes it shorter than a standard ISO 15552 unit of the same bore. This bore uses a 1/4" cylinder port, an M16x1.5 rod thread, and adjustable 21 mm cushions.
Operating strictly within the valve's 0.15-0.8 MPa window, it delivers 982 N push force at 0.5 MPa. This yields a safe working load of roughly 589 N, or a 50 kg vertical lift with a 2:1 margin. The 1/4" valve port provides 16 mm2 flow (Cv 0.89) at up to 5 cycles per second. Because this SKU lacks the S suffix, it cannot accept a magnetic switch.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF50X450-08B |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø50 mm |
| Stroke | 450 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/4" |
| Rod thread | M16×1.5 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-08 (5/2) |
|---|---|
| Valve flow | 16.0 mm² (Cv 0.89) |
| Max frequency | 5 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 982 N | 825 N |
| 0.7 MPa | 1374 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 50×450 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M210-08. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Drives a routing flap on a conveyor line directly from one coil signal, removing the need to run tubing back to a central manifold.
Raises and lowers a pallet stop in a packaging cell, saving manifold space while providing 982 N of push force at 0.5 MPa.
Powers a clamping fixture on a large machine bed without extra plumbing, utilizing the integrated 4M210-08 valve.
Size force between the 50 mm bore (982 N push at 0.5 MPa) and the 63 mm bore (1559 N) based on your load. Verify the DC24V terminal entry and PT threads. The default action retracts the rod when energized, but you can reposition the valve to extend on signal. Always size within the 0.15-0.8 MPa valve limit, not the 1.0 MPa cylinder body rating. The built-in valve routes air and is not a load lock; add an external rod lock or pilot-operated check valve to hold a load. For this 450 mm stroke, use external guides to prevent rod bending and side loads.
Quick checklist
It delivers 982 N push and 825 N pull at 0.5 MPa. The built-in valve is a 4M210-08 (Cv 0.89, 16 mm2 flow) running on DC24V. You must size loads within the 0.15-0.8 MPa valve operating window. The cylinder port is 1/4" and the rod thread is M16x1.5.
No. The built-in valve only routes air; it is not a lock. The rod drifts on air loss. For load holding, install an external rod lock or pilot-operated check valve. Also, note this SKU lacks a magnet and cannot take a sensor.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.