The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF50X600S-06B is a genuine double-acting profile-type cylinder with a Ø50mm bore, 600mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF50X600S-06B is a double-acting profile-type cylinder with a built-in AirTAC 4M210-06 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel is shorter than an ISO 15552 cylinder of the same bore. This 50mm bore unit has a 1/4" cylinder port, an M16x1.5 rod thread, and a 600mm stroke.
The integrated valve has a 1/8" port, 14 mm2 flow (Cv 0.78), and handles 5 cycles/sec. It runs on DC24V with terminal entry. The cylinder body rates to 1.0 MPa, but the valve limits operation to 0.15-0.8 MPa. At 0.5 MPa it pushes 982 N and pulls 825 N. A computed buyer insight: safe working load is ~589 N (60% of the 982 N figure), allowing a vertical lift of ~50 kg with a 2:1 margin. The S suffix means a piston magnet is present for CMSG/DMSG/EMSG switches.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF50X600S-06B |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø50 mm |
| Stroke | 600 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/4" |
| Rod thread | M16×1.5 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 982 N | 825 N |
| 0.7 MPa | 1374 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 50×600 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Decentralized package sorting on a conveyor. The built-in valve switches the 600mm stroke locally, eliminating long tube runs back to a central manifold.
Lifting a 50kg access gate. The self-contained DC24V valve simplifies wiring in large facilities, while the profile barrel resists impact in busy aisles.
Ejecting parts from a machine bed. The 4M210-06 valve delivers 5 cycles/sec, and the adjustable 21mm cushions decelerate the rod at stroke ends.
Size by checking both neighbor bores: the 40mm bore offers 628 N push at 0.5 MPa, while the 63mm bore provides 1559 N. This 50mm bore delivers 982 N push and 825 N pull at 0.5 MPa. Always size force within the valve's 0.15-0.8 MPa window, never the cylinder's 1.0 MPa body rating. Confirm the DC24V coil and terminal entry suit your control system. The rod retracts when energised by default; reposition the valve to extend-when-energised. Because the valve only routes air, it is not a load lock—add an external rod lock or pilot-operated check valve to hold loads. For this 600mm stroke, use external guides to prevent rod bending and side-load wear.
Quick checklist
It pushes 982 N and pulls 825 N at 0.5 MPa. The built-in valve is a 4M210-06 (5/2 solenoid) with a 1/8" port, Cv 0.78, and 5 cycles/sec max. It operates on DC24V. Although the cylinder body rates to 1.0 MPa, the assembled unit must run within the valve's 0.15-0.8 MPa window.
No. The built-in 5/2 valve routes air but does not lock the piston. If air is lost, the rod drifts. For load holding, install an external rod lock or pilot-operated check valve. The default action retracts the rod when energised, but you can reposition the valve to extend-when-energised.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.