The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF80X175S-10B is a genuine double-acting profile-type cylinder with a Ø80mm bore, 175mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF80X175S-10B is an extruded aluminum profile-type double-acting cylinder with a built-in AirTAC 4M310 5/2 solenoid valve on the cap. One DC24V coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The 80mm bore delivers 2513N push and 2268N pull at 0.5MPa. The 3/8" valve port flows 30mm2 (Cv 1.68) at up to 4 cycles/s.
Size force within the 0.15-0.8MPa valve window, as the assembled unit cannot use the 1.0MPa cylinder body rating. Based on the 0.5MPa push force, the safe working load is about 1508N, yielding a 128kg vertical lift capacity with a 2:1 margin. This 175mm stroke includes a piston magnet for position sensing and uses adjustable 28mm cushions. The cylinder port is 3/8" with an M20x1.5 rod thread.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF80X175S-10B |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø80 mm |
| Stroke | 175 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 3/8" |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 2513 N | 2268 N |
| 0.7 MPa | 3519 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 80×175 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Mounts directly at the divert lane to push packages. The integrated 4M310 valve eliminates long tube runs back to a central manifold, improving cycle response.
Ideal for a standalone clamping station on a large machine. One DC24V signal actuates the clamp, saving manifold space and simplifying electrical wiring.
Drives a localized lift gate with a 128kg vertical lift capacity at a 2:1 margin. The built-in piston magnet allows precise position confirmation before lifting.
Select by comparing both ways: the 63mm bore neighbor offers 1559N push at 0.5MPa, while the 100mm bore offers 3927N. This 80mm bore provides 2513N push, making it ideal for mid-range loads. Confirm the DC24V terminal entry and PT thread meet your control specs. The built-in valve routes air but does not lock the load; add an external rod lock or pilot-operated check valve for hold requirements. Default action retracts the rod when energized, but repositioning the valve extends it on signal. Keep operating pressure between 0.15-0.8MPa. At 175mm stroke, side-load is minimal, but ensure standard SC-series mounting guides are used for stability.
Quick checklist
It generates 2513N push and 2268N pull at 0.5MPa. The built-in valve is a 4M310-10 (5/2 solenoid) with a 3/8" port, Cv 1.68, and runs on DC24V. You must size force within the valve's 0.15-0.8MPa operating window, not the 1.0MPa cylinder body rating.
No, the built-in valve only routes air and is not a load lock. The rod drifts on air loss. For load holding, install an external rod lock or pilot-operated check valve. The default action retracts the rod when energized, but you can reposition the valve to extend on signal.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.