The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF80X600-10B is a genuine double-acting profile-type cylinder with a Ø80mm bore, 600mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF80X600-10B is a double-acting profile cylinder with a built-in AirTAC 4M310 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel is shorter than an ISO 15552 cylinder of the same bore. It features a 25mm rod, M20x1.5 thread, 3/8" cylinder port, and 28mm adjustable cushions.
Operating within the valve's 0.15-0.8 MPa window, it delivers 2513N push at 0.5 MPa. A computed buyer insight: safe working load is roughly 1508N, and vertical lift capacity is about 128kg with a 2:1 margin. The 4M310-10 valve provides 30 mm2 flow (Cv 1.68) and handles 4 cycles/sec. This DC24V terminal entry coil is IP65 rated. Note this SKU lacks a magnet and cannot take a sensor.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF80X600-10B |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø80 mm |
| Stroke | 600 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 3/8" |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 2513 N | 2268 N |
| 0.7 MPa | 3519 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 80×600 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Mounts directly on a conveyor diverter arm. The built-in 4M310 valve switches the 80mm bore locally, eliminating long tubing runs back to a central manifold for faster response.
Ideal for pallet handling lines. One DC24V signal actuates the 600mm stroke gate, saving manifold space while providing 1508N safe working load to halt heavy pallets.
Drives a large access door on a machining cell. The self-contained 5/2 valve simplifies wiring, and the profile cylinder body fits compactly without ISO 15552 tie-rods.
Size by checking both neighbors: the 63mm bore yields 1559N push at 0.5 MPa, while the 100mm bore yields 3927N. This 80mm bore provides 2513N push and 2268N pull at 0.5 MPa. Always size force within the 0.15-0.8 MPa valve range, never the 1.0 MPa cylinder body rating. Confirm the DC24V terminal entry meets your control specs. Default action retracts the rod when energized; reposition the valve to extend on signal. Because the 600mm stroke exceeds 300mm, use an external guide to prevent rod bending and side-load wear. For load holding, add an external rod lock or pilot-operated check valve, as the valve only routes air.
Quick checklist
It pushes 2513N and pulls 2268N at 0.5 MPa, reaching 4021N at 0.8 MPa. The built-in valve is a 4M310-10 (3/8" port, Cv 1.68, 30 mm2 flow, max 4 cycles/sec). The cylinder body rates to 1.0 MPa, but you must size force within the valve's 0.15-0.8 MPa operating window. Coil is DC24V, IP65, terminal entry.
No remote valve is needed; the integrated 4M310 valve switches the cylinder with one coil signal. However, it cannot hold a load on air loss. The valve routes air and is not a lock. For vertical loads, install an external rod lock or pilot-operated check valve. Also, since this SKU lacks a magnet, it cannot accept magnetic sensors.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.