verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC 4V Series · 5/3-way Solenoid Valve

Airtac 4V Solenoid Valves 4V230P08C-W

The AirTAC Airtac 4V Solenoid Valves 4V230P08C-W is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with W ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/3-way
  • Function5/3 double solenoid — Closed center
  • Port sizeW
  • Effective area13.6 mm²
  • Flow (Cv)0.8
  • Series4V200
$71.25 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V230P-08 stroke, mounting and version on one page All 4V230P-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 4V Solenoid Valves 4V230P08C-W

The 4V230P-08C-W is the external-pilot (-W) version of AirTAC's 5/3 pressure-center valve in the 4V200 mid-body class. Fitted with an AC110V coil rated at 4.5 VA in a terminal-box entry, it switches compressed air to a double-acting cylinder or actuator through PT 1/4" ports. In the center position both cylinder ports A and B are pressurised, so the actuator is held against drift from either direction while exhaust stays blocked.

Because this SKU uses an external pilot supply, the spool is shifted by pilot air fed to a separate pilot port rather than tapped from the main line. That keeps switching dependable where main-line pressure dips, sags under load, or runs in low-pressure and vacuum circuits. The pressure-center spool gives an effective area of 13.6 mm2 (Cv 0.8) with a 3 cycle/sec maximum frequency, and the whole 360 g valve responds in 0.05 s or less. Like all 4V200 bodies it is IP65 (DIN40050), carries a locking or non-locking manual override, and mounts on a base for an integrated manifold group. It suits roughly O32-50 mm double-acting cylinders.

Airtac 4V Solenoid Valves 4V230P08C-W Technical Specifications

ModelAirtac 4V Solenoid Valves 4V230P08C-W
Series4V200 solenoid valve (spool type)
Valve type5/3-way
Function5/3 double solenoid — Closed center
Port sizeW
Exhaust portW
Effective area (Cv)13.6 mm² (Cv 0.8)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight360 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area13.6 mm²
Flow coefficientCv 0.8
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: Airtac 4V Solenoid Valves 4V230P08C-W

4VSolenoid valve, spool type, 4-series.
2Body size (4V200) — sets port & flow.
3Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-WPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the Airtac 4V Solenoid Valves 4V230P08C-W Is Used

valve

Low-pressure and vacuum circuit switching

The external pilot port lets the 5/3 spool change over even when the main line runs at reduced pressure or under vacuum, where an internally piloted valve would fail to shift.

settings_input_component

Assembly and test stations

Pressure-center hold on both cylinder ports keeps a pusher, lift, or nesting fixture pressurised from both sides during a stopped mid-cycle state, while the AC110V terminal box ties straight into standard control panels.

speed

Packaging and clamping actuators

With Cv 0.8 flow and a 0.05 s response, this valve cycles O32-50 mm double-acting clamp and eject cylinders up to 3 times per second on packaging and handling equipment.

Is the Airtac 4V Solenoid Valves 4V230P08C-W the Right Valve?

Match five points when replacing: 4V200 body, 5/3 pressure-center double-solenoid function, 1/4" PT port, AC110V coil, and terminal-box entry - plus the -W external-pilot option, which matters if your circuit cannot guarantee main-line pressure at the pilot stage. If your cylinder does not need a center function, the 5/2 double-solenoid 4V220 in this same body flows more (17.0 mm2, Cv 1.0, 5 cycle/sec). Step down to the 4V100 (Cv 0.6) for small bores, or up to the 4V300 (Cv 1.65) for larger cylinders and faster cycling.

A pressure center suits actuators that must resist movement from both ends while stalled, but it is not a certified brake. Where a suspended or hazardous load demands guaranteed holding, add a pilot-operated check valve at the cylinder ports or a mechanical brake. For multiple valves in one compact block, specify this model on a manifold base instead of individual piping.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

Airtac 4V Solenoid Valves 4V230P08C-W FAQ

It directs compressed air to double-acting cylinders and actuators in the O32-50 mm bore range. The 5/3 pressure-center spool has an effective area of 13.6 mm2 (Cv 0.8) versus 17.0 mm2 (Cv 1.0) for the 5/2 version of this body, and a 3 cycle/sec maximum frequency instead of 5, because the center-position flow paths restrict the passage.

-W is the factory external-pilot option: pilot air for shifting the spool comes from a dedicated external port instead of being taken internally from the main supply. Choose it when your main-line pressure can drop too low to shift the valve reliably - for example in low-pressure or vacuum circuits, or on lines that sag under peak demand. Everything else matches the standard 4V230P-08C: 5/3 pressure center, PT 1/4" ports, AC110V 4.5 VA coil, and terminal-box entry.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 4V Solenoid Valves 4V230P08C-W

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V230P08C-W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.