verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC 4V Series · 5/3-way Solenoid Valve

Airtac 4V Solenoid Valves 4V430E15BT

The AirTAC Airtac 4V Solenoid Valves 4V430E15BT is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with 430E15BT ports and an effective area of 40.0 mm² (Cv 2.35). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/3-way
  • Function5/3 double solenoid — Exhaust center
  • Port size430E15BT
  • Effective area40.0 mm²
  • Flow (Cv)2.35
  • Series4V400
$98.28 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 4V Solenoid Valves 4V430E15BT

The AirTAC 4V430E-15BT is a 5/3-way double-solenoid valve with an exhaust center, built on the 4V400 body and delivered in a 1/2 in NPT configuration with a DC24V coil drawing 3.0 W from a sealed terminal box. When neither coil is energised, both cylinder ports A and B vent to exhaust, so the actuator floats free - a mechanic can push a Dia100 press ram or slide a fixture into place by hand between cycles, then pulse a solenoid to re-engage. With a pulse applied, the valve shifts and directs air to one side of a double-acting cylinder while the other side exhausts. Flow sits in the 4V400 large-bore class: 40.0 mm2 effective area (Cv 2.35) through the 5/3 spool, moving cylinders in roughly the Dia80-125 mm range. Shift response is 0.05 s or less and the valve cycles up to 3 times per second. The spool-type construction, IP65-rated terminal box and locking or non-locking manual override make it a dependable mid-stroke FLOAT valve for US-plumbed NPT circuits, and the 770 g aluminium body stacks onto a common base as part of an integrated manifold group.

Airtac 4V Solenoid Valves 4V430E15BT Technical Specifications

ModelAirtac 4V Solenoid Valves 4V430E15BT
Series4V400 solenoid valve (spool type)
Valve type5/3-way
Function5/3 double solenoid — Exhaust center
Port size430E15BT
Exhaust port430E15BT
Effective area (Cv)40.0 mm² (Cv 2.35)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight770 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area40.0 mm²
Flow coefficientCv 2.35
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: Airtac 4V Solenoid Valves 4V430E15BT

4VSolenoid valve, spool type, 4-series.
4Body size (4V400) — sets port & flow.
3Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-430E15BTPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V410 (single), 4V420 (double), 4V430C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the Airtac 4V Solenoid Valves 4V430E15BT Is Used

valve

Die-change ram positioning on pneumatic presses

Exhaust center lets a Dia100 press ram (about 400 kgf push at 0.5 MPa) float so operators can nudge the die into position by hand, then a DC24V pulse re-pressurises within 0.05 s to resume the stroke.

conveyor_belt

Sawmill log-transfer pushers

A Dia125 push cylinder delivers roughly 626 kgf at 0.5 MPa to kick logs onto a slat conveyor; the 1/2 in NPT ports and Cv 2.35 flow keep transfer strokes fast at up to 3 cycles per second.

engineering

Manual-jog gate diverters in recycling plants

Between pulses the floating center lets maintenance staff swing a heavy waste-sorting gate freely for jam clearing, with the terminal box giving IP65-protected wiring on the dusty line side.

Is the Airtac 4V Solenoid Valves 4V430E15BT the Right Valve?

Size in both directions. If your cylinder is below about Dia80 mm (roughly 256 kgf push at 0.5 MPa on a Dia80 bore), step down to the 4V300 body with its Cv 1.65 - it is cheaper and faster-cycling for that load. The 4V400 is the largest 4V body, so if Cv 2.35 still starves a Dia125 cylinder (about 626 kgf push at 0.5 MPa) or you need more than 3 cycles per second, move up to a larger AirTAC valve series or split the circuit across a manifold. Choose 30E when the mid-position should let the actuator drift for manual adjustment or free movement; choose 30C if the load must hold still at center, or 30P if both sides should stay pressurised. For a drop-in replacement, match five points on the old label: body size 4V400, function 30E, 1/2 in port with NPT thread, DC24V coil, and terminal-box electrical entry. A code reading 4V430E-15B or 4V430E-15BIG differs in thread or wiring and will not bolt onto the same piping without adapters.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

Airtac 4V Solenoid Valves 4V430E15BT FAQ

Flow: 40.0 mm2 effective area, Cv 2.35 through the 5/3 spool, with a maximum cycling rate of 3 cycles per second. Response (activating) time is 0.05 s or less. Operating pressure is 0.15-0.8 MPa with a 1.2 MPa proof pressure. The DC24V coil draws 3.0 W, insulation is class B and protection is IP65 (DIN40050). The aluminium-alloy body weighs 770 g, operates from -20 to +70 C, needs air filtered by a 40 um element, and requires no lubrication.

At center, both cylinder ports vent to exhaust, so a double-acting actuator floats free and can be moved by hand or by the load - ideal for manual jogging and setup work. It is not a load-holding position: a suspended or vertical load will drift or fall. Where guaranteed holding is required, fit pilot-operated check valves at the cylinder ports or a mechanical brake, and use the 30C closed-center version instead if the cylinder must stop dead at mid-stroke.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 4V Solenoid Valves 4V430E15BT

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V430E15BT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.